Summary of Contents for Duco DUCOBOX SILENT CONNECT 400

  • Page 1 DucoBox Silent Connect ENGLISH Product version 17xxxx and above Installation guide Step by step duco.tv instructions L2000641 (Revision G | 17.07.2019)
  • Page 2: Table Of Contents

    DUCO, HANDELSSTRAAT 19 VEURNE, B-8630 Vero Duco - Handelsstraat 19 - 8630 Veurne - Belgium tel +32 58 33 00 33 - fax +32 58 33 00 44 - info@duco.eu - www.duco.eu L2000641 Installation guide for DucoBox Silent (Revision G | 17.07.2019)
  • Page 3: Introduction

    0�65 = control based on 2 or more sensors Air supply options: With Duco's Demand-Controlled Natural Ventilation Systems, there is a choice from a wide range of self-regulating (SR) window ventilators available for the fresh air supply� From standard self-regulating louvres which can be fitted in every kind of window or installation site, to louvres with sound absorbing qualities for projects where there is exposure to (mild) levels of noise, fire-resistant louvres, custom louvres for high-rise buildings, to ventilation and solar shading in a single product or electronically controlled louvres with preheating�...
  • Page 4: Fitting

    10 NIET TE MISSEN TIPS connections Keep down restriction� A non-return flap is De goede werking van uw Duco ventilatiesysteem is volledig afhankelijk van de keuze en uitvoeringskwaliteit van de afvoerleidingen! required when discharging into a manifold� Be sure to take note of the ‘10 unmissable tips’...
  • Page 5: Wiring

    04.B Cabling diagram The DucoBox Silent Connect is able to communicate with Duco slave components via a wireless (RF) or wired link� Both types of communication can be combined in one system� Communication with non-Duco components is possible via the Switch Sensor or one of the connections on the optional Communi- cation Print (see page 7)�...
  • Page 6: Additional Control Options

    Connect the Boxsensors to one of the two connectors provided on the DucoBox Silent Connect PCB� Settings CLICK The CO and RH setpoint can be changed using the Duco Network Control Tool� See www�duco�eu for more information� DucoBox L2000641 Installation guide for DucoBox Silent (Revision G | 17.07.2019)
  • Page 7: 05�B Communication Print

    This can be done using the Duco Network Tool*� This user-friendly software also enables problems in the system to be pinpointed� The Duco Network Tool is issued to every installer af- ter attending a free training course at the Duco Academy*� Please refer to our website or your Duco dealer for further information�...
  • Page 8: 06�C Led Indications

    ENGLISH 06.C LED indications RED (blinking slowly) RED (blinking rapidly) Not in network Logging in GREEN (blinking slowly) GREEN (blinking rapidly) In network In network, waiting for associated components YELLOW (clignotement rapide) YELLOW (on) Initialising (system Transitional phase (please wait) configuration in progress) WHITE or OFF Normal...
  • Page 9: 06�E Pairing Components

    ENGLISH 06.E Pairing components Never pair more than one system with RF components at the same time. If you do so, a component in the wrong network could be paired, e.g. in the neighbours’ DucoBox. Example of a pairing sequence Pairing components on the DucoBox Silent Connect Activate ‘Installer mode’...
  • Page 10: Air Calibration

    The system needs to be configured for it to work correctly� This will ensure its operation is as quiet as possible and energy-efficient� See under the Tools heading at www�duco�eu for information about determining ventilation flow rates� 07.A Air calibration procedure for DucoBox Silent Connect The air calibration procedure must be carried out on a calm day (no more than wind force 2: leaves rustling, fee- ling the wind in one’s face)�...
  • Page 11 ENGLISH Press ‘HIGH’ or ‘LOW’ to activate the configuration mode for 30 minutes� Then close the cover firmly. Which configuration mode should I choose? Air calibration using 'HIGH' Air calibration using 'LOW' This method is standard and has the This method offers a boost mode Button HIGH lowest consumption�...
  • Page 12: 07�B Checking

    All warranty conditions concerning the DucoBox and Duco's ventilation systems can be found on the Duco website� All complaints are to be reported to Duco by the Duco distributor with a clear description and the order/invoice number under which the products were delivered� In order to register the complaint, please use the complaint registration form found on the Duco website and the product's serial number in your message to service@duco�eu�...
  • Page 13 ENGLISH L2000641 Installation guide for DucoBox Silent (Revision G | 17.07.2019)
  • Page 14 ENGLISH L2000641 Installation guide for DucoBox Silent (Revision G | 17.07.2019)
  • Page 15 ENGLISH L2000641 Installation guide for DucoBox Silent (Revision G | 17.07.2019)
  • Page 16 ENGLISH Installed by: L2000641 Document last modified on 17.07.2019 (revision G) L2000641 Installation guide for DucoBox Silent (Revision G | 17.07.2019)