4.2.4 Network exception and processing

There are two failure scenarios. Type one: fail to assign netkey; Type two: fail to bind APPkey.
The solution to assign netkey failure is as follows:
To deal with the failure to assign netkey, user needs to repeat the above networking process.
The solution to the failure to bind APPkey is as follows:
Method 1. If the user knows which E104_BT10N device is used, directly restore the E104_BT10N device to the
factory (see details from 3.1.17) and repeat the above networking process again.
Method 2: The serial port reads the next networking address "A" of E104_BT10G (see details from 3.1.6), and then
uses the SIGmesh command to delete the device whose node address is "A minus 3" (see details from3.2 SIG message),
and the above networking process is repeated again.

4.2.5 Remove nodes

The instruction to delete a node can only be sent by E104_BT10G of the current network, and it returns. If it is not
deleted, it is not returned.
See the manual (3.2 SIG message) for instructions and usage details.

4.3 Data format

All data exchanged by the serial port, including parameter configuration, network control, and data transparent
transmission, meet the following format requirements. Any remaining data will be considered invalid and the module will
not respond. The parameter configuration is used for parameter configuration of the current module, the SIG message is a
standard mesh control message defined by sig, and the transparent transmission message is defined by Ebyte.

4.3.1Parameter configuration

The configuration data is used to read and write various parameter information of the module and the device access
operation. The format is as follows:
Transmitting
Notes: The correct configuration operation gets the corresponding response data. If the configuration error returns
an error code, as follows
hengdu Ebyte Electronic Technology Co., Ltd
Copyright ©2012–2019,C
Length(1byte HEX)
N
command (1byte) Operation code(1
0xC0
Receiving
0x40
Error code
0xFF
0xFE
Effective load(N byte HEX)
Parameter configuration
SIG message
Transparent transmission message
Data(N byte)
byte)
0~255
0~255
Explain
Invalid parameter
Busy operation
E104-BT10-IPX User Manual
Request data
Respond data
4-13