Ebyte E104-BT10-IPX User Manual page 18

Uart smd sig mesh module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd
Request
Respond
For
Request:02 C0 09
example
Respond:0B 40 09 112233445566 0004 03
Notes:
1、Suitable for E104-BT10G-IPX
2、Return MAC of networking device and assigned unicast address and element
numbers
11.Baud rate configuration
Request
Respond
For
example
Notes:
1、Suitable for E104-BT10G-IPX and E104-BT10N-IPX
2、For example 3 C0 0E 02, when succeed, return 03 40 0E 02, if exceed range, return
03 40 0E FF
12. To read baud rate
Request
Respond
For
example
hengdu Ebyte Electronic Technology Co., Ltd
Copyright ©2012–2019,C
code
0x09
Return MAC of networking device and assigned unicast
0x09
Operation code
Baud rate serial number to be configured(range:
0x0E
0x00~0x07)
Return the current baud rate serial number
0x0E
Command
Baud rate serial number notes
03 C0 0E xx
Xx is baud rate serial number to be configured
(0x00~0x07)
00:230400
01:128000
02:115200
03:76800
04:57600
05:19200
06:9600
07:4800
Operation code
0x0F
0x0F
Command
02 C0 0F
/
address and element numbers
Parameter
Parameter
/
Return the current baud rate serial number
Return
03 40 0F xx
Xx is baud rate number
00:230400
01:128000
E104-BT10-IPX User Manual
Notes
4-17

Advertisement

Table of Contents
loading

Table of Contents