Agent Access And App Configuration Network Access; Data Format - Ebyte E104-BT11 User Manual

Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd
proceed as follows:
There must be nodes in the role of Friend near the same network;
The PC03 pin of BT11 is pulled up to VCC;
When configuring the node to connect to the network (BT11-G or APP), enable LPN and prohibit relay and friend. The
proxy function can be disabled according to user needs;
After completing the above three steps, you can use low-power nodes. Of course, users can also change LPN parameters
according to their actual needs.

5.3 Agent access and APP configuration network access

BT11 supports the agent role. Users can connect to the agent node through the APP and communicate within the network.
Regarding APP development, Ebyte provides Android and IOS platform SDKs, examples and Demo. The directory structure is as
follows.
Due to the fact that the BT11-G module configuration node has a maximum of 13 network access data. It is strongly
recommended that users can configure the network through the development of APP.
Ebyte's BT11 uses the manufacturer's custom model.
Manufacturer ID
Operation code
Note:
The operations that must be performed when developing APP configuration to access the network: binding
APPKEY, publishing and subscribing to our company's modules. Otherwise, communication cannot be achieved.
The data format of the data packet when publishing data through the proxy node is as follows, where if the target
address is 0xffff, it is broadcast within the group:
Target address

5.4 Data format

All data exchanged by the serial port of the module, including parameter configuration, network control, and data transparent
transmission, comply with the following format requirements. Any remaining data will be considered invalid and the module will not
respond. The parameter configuration is used for the parameter configuration of the current module. The SIG message is a standard
mesh control message defined by sig, and the transparent transmission message is a customized data transparent transmission message