Ebyte E104-BT10-IPX User Manual page 21

Uart smd sig mesh module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd
1、Suitable for E104-BT10G-IPX and E104-BT10N-IPX
2、Status value 00 means succeed
18. To obtain software version number
Operation
Request
Respond
For
Request:02 C0 16
example
Respond:04 40 16 10 00
Notes:
1、Suitable for E104-BT10G-IPX and E104-BT10N-IPX
2、software version number is an unique value
19.To obtain main address of current device
Operation code
Request
Respond
For
Request:02 C0 0B
example
Respond:05 40 0B 01 0004
Notes:
1、Suitable for E104-BT10G-IPX and E104-BT10N-IPX
2、return unicast address of E104-BT10N-IPX device in current network
Set whether enter sleep and timeout for entering sleep
20.
Operation
code
Request
0x17
Respond
0x17
For
Request:03 c0 17 05
example
Respond:03 40 18 05
Notes:
1、 Suitable for E104-BT10N-IPX
2、 Set parameter 05 to the sleep timeout after the serial port stops working.,unit:
S, range: 0X01-0XFF,parameter 00 means do not enter sleep.
hengdu Ebyte Electronic Technology Co., Ltd
Copyright ©2012–2019,C
code
0x16
0x16
0x0B
Return main address of current E104-BT10N-IPX
0x0B
Parameter
/
Set whether E104-BT10N-IPX enter sleep and timeout for
entering sleep
Parameter
/
software version number
Parameter
/
device
E104-BT10-IPX User Manual