Parallel Audio Stage-100 Series Operation Manual page 10

Uhf 100-frequency 2-way synchronising true diversity receiver
Table of Contents

Advertisement

UHF BELTPACK TRANSMITTER (BP9000)
Parts and Functions
1.
Antenna
2.
LCD
3.
Cover release button
4.
Power switch
5.
IrDA synchronising button
6.
Menu button
7.
Setting button
8.
High-impedance gain control (GT)
Channel Synchronising of the Receiver and Transmitter
Sync Channel from Transmitter Ú Receiver
PLL CALL
STEP 1: Press the synchronising button of the
transmitter.
STEP 2: IRDA PLL CALL will appear on the transmitter's
LCD to denote synchronising the receiver's channel.
STEP 3: If the receiver's channel is synchronised,
PLL SEND OK will appear. Please try again if the LCD
shows IRDA FAIL.
If it doesn't work check that you have the IR sensor panels aligned, that they are facing each other, devices are within
30cm of each other, and try again.
PAGE 10
9.
Low-impedance gain control (MT)
10.
Battery compartment
11.
Audio mute switch
12.
Battery power LED
13.
IrDA sensor area
14.
Mini XLR connector
15.
Charging contacts
Align infrared areas of the receiver and transmitter within 10~30cm.
IRDA
PLL SEND
OK
Sync Channel from Receiver Ú Transmitter
650.000M
STEP 1: Press the SYNC button of the receiver.
STEP 2: The receiver's LCD will display IRDA DATA SEND to
denote synchronising signal being sent.
STEP 3: The channel/frequency of the transmitter will
change. Synchronisation is complete when the LCD displays
PLL CHANNEL COPIED BY IRDA.
STEP 4: Please try again if LCD displays IRDA SEND FAIL..
CH:001
CH:010
652.250M
OPERATION MANUAL V1.0