Parallel Audio Stage-100 Series Operation Manual page 8

Uhf 100-frequency 2-way synchronising true diversity receiver
Table of Contents

Advertisement

UHF HANDHELD MICROPHONE (HH9000)
Parts and Functions
1.
Cartridge
2.
Battery power LED
3.
Power switch
4.
LCD
5.
Menu button
6.
Setting button
Channel Synchronising of the Receiver and Transmitter
Sync Channel from Transmitter Ú Receiver
PLL CALL
STEP 1: Press the synchronising button of the
transmitter.
STEP 2: IRDA PLL CALL will appear on the microphone's
LCD to denote synchronising the receiver's channel.
STEP 3: If the receiver's channel is synchronised,
PLL SEND OK will appear. Please try again if the LCD
shows IRDA FAIL.
If it doesn't work check that you have the IR sensor panels aligned, that they are facing each other, devices are within
30cm of each other, and try again.
PAGE 8
Align infrared areas of the receiver and transmitter within 10~30cm.
IRDA
PLL SEND
OK
7.
IrDA synchronising button
8.
Battery compartment
9.
Colour cap
10.
IrDA sensor area
11.
Charging port
Sync Channel from Receiver Ú Transmitter
650.000M
STEP 1: Press the SYNC button of the receiver.
STEP 2: The receiver's LCD will display IRDA DATA SEND to
denote synchronising signal being sent.
STEP 3: The channel/frequency of the transmitter will
change. Synchronisation is complete when the LCD displays
PLL CHANNEL COPIED BY IRDA.
STEP 4: Please try again if LCD displays IRDA SEND FAIL..
CH:001
CH:010
652.250M
OPERATION MANUAL V1.0

Advertisement

Table of Contents
loading