Battery Installation and Indicator
This microphone requires 2 x AA batteries to operate.
To install, remove the battery cover and slide the batteries according to the correct polarity into the battery
compartment and replace the battery cover.
Note: Batteries contain a corrosive acid that may leak and damage the microphone when stored for a long period.
Batteries should be removed from the microphone if it is not to be used for a prolong period of about 4 weeks or more.
When the microphone is switched ON a blue LED (2) will blink once to indicate the batteries installed are in good
condition. If the LED remains illuminated, it means the batteries are weak and replacement is required.
Channel Setting
1.
Use MENU button (5) to go to the CHANNEL | BATTERY STATUS page.
2.
The upper-right channel number will flash to allow changes to be made.
3.
Press SET button to change the channel number. 5 seconds after selecting a channel, it will be automatically saved.

Battery Type Setting

1.
Use MENU button (5) to go to the BATTERY TYPE page.
2.
Press SET button (6) for 3 seconds, then the cursor Ù will flash to allow changes to be made.
3.
Press SET button to select either NiMH (rechargeable battery) or AKLN (alkaline battery). 5 seconds after selecting
a battery type, it will be automatically saved.
Important: NiMH battery must be selected when rechargeable battery is being used. Never select AKLN (alkaline) when
microphone is intended for charging as alkaline battery isn't rechargeable. Wrong battery selection will result in battery
sensing electronics to display wrong and misleading status information.
OPERATION MANUAL V1.0
CH:001
NIMH
AKLN
CH:010
NIMH
AKLN