6-3. Heating capacity
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
¢ Model: AOU18RLXFZ
• TC: Total Capacity, IP: Input Power
• The data is based on the following conditions:
Pipe length: 24.6 ft (7.5 m), Height difference: 0 ft (0 m) [Outdoor unit—Indoor unit]
Indoor units: 7,000 Btu
°FDB
°FDB
°FWB
5
3
14
12
23
19
32
28
41
37
47
43
50
47
59
50
68
59
75
65
°CDB
°CDB
°CWB
-15.0
-16.1
-10.0
-11.1
-5.0
-7.2
0.0
-2.2
5.0
2.8
8.3
6.1
10.0
8.3
15.0
10.0
20.0
15.0
23.9
18.3
6-3. Heating capacity
60
65
TC
IP
TC
kBtu/h
kW
kBtu/h
8.16
1.06
7.90
9.31
1.13
9.02
9.73
1.08
9.42
10.16
1.03
9.83
11.45
0.96
11.08
12.21
0.96
11.82
12.30
1.00
11.91
12.42
0.96
12.03
12.18
0.76
11.79
10.96
0.57
10.61
15.6
18.3
TC
IP
TC
kW
kW
2.39
1.06
2.32
2.73
1.13
2.64
2.85
1.08
2.76
2.98
1.03
2.88
3.35
0.96
3.25
3.58
0.96
3.46
3.60
1.00
3.49
3.64
0.96
3.53
3.57
0.76
3.46
3.21
0.57
3.11
Indoor temperature
70
IP
TC
IP
kW
kBtu/h
kW
1.09
7.64
1.12
1.17
8.71
1.20
1.11
9.10
1.15
1.06
9.50
1.09
0.99
10.71
1.01
0.99
11.42
1.02
1.03
11.51
1.06
0.99
11.62
1.02
0.78
11.39
0.80
0.59
10.25
0.61
Indoor temperature
21.2
IP
TC
IP
kW
1.09
2.24
1.12
1.17
2.55
1.20
1.11
2.67
1.15
1.06
2.78
1.09
0.99
3.14
1.01
0.99
3.35
1.02
1.03
3.37
1.06
0.99
3.41
1.02
0.78
3.34
0.80
0.59
3.01
0.61
- 190 -
75
78
TC
IP
TC
kBtu/h
kW
kBtu/h
7.37
1.15
7.21
8.41
1.23
8.22
8.78
1.18
8.59
9.17
1.12
8.97
10.34
1.04
10.11
11.02
1.05
10.78
11.10
1.09
10.86
11.21
1.04
10.97
10.99
0.83
10.75
9.90
0.62
9.68
23.9
25.6
TC
IP
TC
kW
kW
2.16
1.15
2.11
2.46
1.23
2.41
2.57
1.18
2.52
2.69
1.12
2.63
3.03
1.04
2.96
3.23
1.05
3.16
3.25
1.09
3.18
3.29
1.04
3.21
3.22
0.83
3.15
2.90
0.62
2.84
6. Capacity table
IP
kW
1.17
1.25
1.20
1.13
1.06
1.07
1.11
1.06
0.84
0.63
IP
1.17
1.25
1.20
1.13
1.06
1.07
1.11
1.06
0.84
0.63