Error Code List (LKRA-PCAB1)

Error code Category
E01
PIT:(Projector
Communication)
E02
E03
E06
CAM:(Camera
Communication)
E43
ADJ:(Adjustment) NO SCREEN
E53
E54
Error message
Possible cause
NO CONNECTION
• The calibration camera and
projectors are not connected via
the supplied connection cables.
• The connection cables are
damaged.
• The power switch at the rear of the
projector is set to off (a).
NO COMM
• The calibration camera's CTRL2
connector and the main projector's
RS-232C connector are not
connected via the supplied
connection cable.
• The calibration camera's CTRL2
connector is connected to a device
other than the main projector.
• The connection cables are
damaged.
• The SDCP protocol's
"Community" is set to a setting
other than "SONY."
UNCONTROLLABLE
• The projector is not running.
NO COMM
• The calibration camera's
connection cable is disconnected.
• The calibration camera is
malfunctioning.
• The screen is not within the
shooting range of the calibration
camera.
NO WINDOW
• The test pattern is not detected near
the center of the calibration
camera's frame.
XPT DETECTION
• The calibration points on the
screen are not detected.
44
Solution
• Check the connections, and make
sure the supplied connection cables
are connected properly.
• Use new connection cables. For
details on replacement, contact
your local Sony representative.
• Turn on the projector's main power
by setting the switch to on (|).
• Check the connections, and make
sure the supplied connection cables
are connected properly.
• Use new connection cables. For
details on replacement, contact
your local Sony representative.
• Check the "Community" setting.
• Verify that the MAIN indicators
and LIGHT indicators are lit green.
• Check the connection, and make
sure the cable is connected
properly.
• Contact your local Sony
representative.
• Adjust the position of the
calibration camera so that the
screen is within range.
• Lower the ambient light.
• Adjust the position of the
calibration camera so that the cross
cursor displayed in the LCD panel
appears on the test pattern.
• Lower the ambient light.
• Play back an adjustment CPL with
the same screen aspect ratio as the
[OPTION] - [PIT THROW
RATIO] setting.
• Adjust the position and zoom of
the calibration camera so that the
four sides of the test pattern
displayed in the LCD panel appear
as vertically and horizontally
straight as possible.
• Adjust the position of the
calibration camera so that reflected
light from the port glass does not
enter the camera.