V2 AYROS series Manual page 41

230v/120v electro-mechanical irreversible rack actuator for sliding gates up to 1200 kg
Hide thumbs Also See for AYROS series:
Table of Contents

Advertisement

Available languages

Available languages

L
Power phase 230 Vac
N
Neutral 230 Vac
B1 - B2
Flashing light 230Vac - 40W
B3 - B3
Courtesy light
M1
START - Open command for connecting
traditional devices with N.O. contact
m
WARNING: If you use maintained
command devices (magnetic loop detectors,
timers, presence detectors, etc.) clock mode
must be used (parameter
M2
START P. - Pedestrian open command for
connecting traditional devices with N.O. contact
m
WARNING: If you use maintained
command devices (magnetic loop detectors,
timers, presence detectors, etc.) clock mode
must be used (parameter
M3
STOP command. N.C. contact
M4
Common (-)
M5
Photocell 1. N.C. contact
M6
Photocell 2. N.C. contact
M7
Type 1 edges. N.C. contact
M8
Type 2 edges. N.C. contact
M9
Accessories common (-)
M10
24Vac supply for photocells and other
accessories
M11
Accessory power common (-)
M12
24Vac supply - photocell/optical edge TX for
functional Test.
Connect power supply cables of photocells
transmitter between terminals M11 and M12
A1
Antenna shield
A2
Antenna
ADI
ADI module interface
RECEIVER
Plug-in receiver
FUSE
10A
MAINS
It shows that the control unit is power supplied
OVERLOAD It shows that there is an overload on accessories
power supply
Strt
oroL
=
).
Strt
oroL
=
).
- 39 -
4.10 - PLUG IN RECEIVER
PD19 control unit is suitable for plugging in a MR receiver having
a high-sensitivity super-heterodyne architecture.
m
WARNING: Pay attention to the way you connect the
removable modules.
MR module receiver is provided with 4 channels and each of
them is suitable for a command of PD19 control unit:
g
• CHANNEL 1
START
g
• CHANNEL 2
PEDESTRIAN START
g
• CHANNEL 3
STOP
g
• CHANNEL 4
COURTESY LIGHT
NOTE: Before programming 4 channels and function logics
read carefully the instructions of MR.
4.11 - ADI INTERFACE
The ADI (Additional Devices Interface) interface of the control unit
PD19 allows the connection to V2 optional modules.
Refer to V2 catalogue or to the technical sheets to see which
optional modules with ADI interface are available for this control
unit.
m
WARNING: Please read the instructions of each single
module to install the optional modules.
For some devices, it is possible to configure the mode for
interfacing with the control unit; in addition, it is necessary to
enable the interface so that the control unit can process the
signals arriving from the ADI device.
i.Adi
Please refer to the
programming menu to enable the ADI
interface and access the device configuration menu.
ADI devices use the display of the control unit to issue alarms or
display the configuration of the control unit.
The device connected to the Adi interface is able to signal to the
control unit three alarm signals, which are displayed on the
control unit display as follows:
• PHOTOCELL ALARMS - the upper segment comes on: the gate
stops moving, when the alarm stops opening restarts.
• EDGE ALARM - the lower segment comes on: inverts motion of
the gate for 3 seconds.
• STOP ALARM - both segments start flashing: the gate stops
and cannot restart until the alarm stops.
• SLAVE - segment steadily lit: it is used by the optional module
SYNCRO to indicate that the control unit is configured as
SLAVE.
STOP ALARM
PHOTOCELL ALARM
EDGE ALARM
SLAVE