Introduction - Oriental motor AZM14*K Series Operating Manual

Stepping motor and driver package alphastep az series/motorized actuator equipped with az series dc power input
Table of Contents

Advertisement

Introduction

1
Introduction
 Before use
Only qualifi ed personnel of electrical and mechanical engineering should work with the product.
Use the product correctly after thoroughly reading the "2 Safety precautions" on p.5. In addition, be sure to
observe the contents described in warning, caution, and note in this manual.
The product described in this manual has been designed and manufactured to be incorporated in general industrial
equipment. Do not use for any other purpose. Oriental Motor Co., Ltd. is not responsible for any damage caused
through failure to observe this warning.
This manual, unless otherwise noted, explains using fi gures of the built-in controller type driver.
 Operating Manuals for the AZ Series
Operating manuals for the AZ Series DC power input type are listed below.
After reading these manuals, keep them in a convenient place so that you can reference them at any time.
The "AZ Series Function Edition" does not come with the product. For details, contact your nearest Oriental Motor
sales offi ce or download from Oriental Motor Website download page.
Type of operating manual
OPERATING MANUAL Driver
(this document)
AZ Series Function Edition
 General specifi cations
Degree of protection
Operation
environment
Storage
environment,
Shipping
environment
Insulation resistance
 RS-485 communication specifi cation
Electrical characteristics
Communication mode
Transmission rate
Protocol
Number of connectable units
* If the motor cable or power supply cable generates an undesirable amount of noise depending on the wiring or
confi guration, shield the cable or install a ferrite core.
▌2
This manual explains the functions as well as the installation/connection method
and others for the driver.
This manual explains driver functions, data setting methods, operating methods
and others which are not described in the operating manual.
Ambient temperature
Humidity
Altitude
Surrounding atmosphere
Ambient temperature
Humidity
Altitude
Surrounding atmosphere
Compliant with EIA-485, straight cable
Use a twist pair cable (TIA/EIA-568B CAT5e or higher is recommended) and keep
the total wiring distance up to 50 m (164 ft.). *
Half-duplex communication
Asynchronous mode (data: 8 bits, stop bit: 1 bit/2 bits, parity: none/even
number/odd number)
Selectable from 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps, and
230,400 bps
Modbus RTU mode
Up to 31 units can be connected to one master controller.
Description of operating manual
IP10
0 to +50 °C (+32 to +122 °F) (non-freezing)
85% or less (non-condensing)
Up to 1000 m (3300 ft.) above sea level
No corrosive gas, dust, water or oil
−25 to +70 °C (−13 to +158 °F) (non-freezing)
85% or less (non-condensing)
Up to 3000 m (10000 ft.) above sea level
No corrosive gas, dust, water or oil
100 MΩ or more when 500 VDC megger is applied between
the following places:
· PE terminal - Power supply terminals