5 – FUNCTIONING AND USE
CAUTION
If during normal running operation the computer detects an irregular condition (not constant
cycling, low pressure, etc...) the system switches off automatically after 20 sec, and STOP led
will start flashing. To make watermaker run again, it is first necessary to press STOP button (in order
give a feedback to the system that the issue has been recognized). Before pressing STAR to run the
watermaker again, be sure to individuate the cause of the anomaly and solve the issue.
5.4.3

Single washing operation

To perform a single washing operation, which flushes the system with fresh water for around 10 minutes in
order to avoid membranes to remain full of salt for long time, it is necessary to push the WASHING button for
more than 3 seconds.
The display will indicate the remaining time. It is possible anyway to stop the operation at anytime by pushing
STOP.
5.4.4

Periodic washing

In order to program a periodic washing, which let the system rinsing automatically with a desired frequency,
please follow the instruction below:
-
Select the days (between 6 and 10) in the "periodic washing" option within the menu
-
Exit from the menu by pushing STOP button
-
Push the WASHING button for 3 seconds
NOTE
In case the power supply is removed, it is necessary to set again the parameter.
5.4.5

Automatic functioning with level controls (optional)

To activate the automatic start/stop from floating switches, please enter in the menu and set Level Control to
ON . Then exit from the menu by pushing STOP.
1. Push START for starting the watermaker,
functioning under the floating switches
control.
Now the start/stop is under the control of the floating
switches. Once the tank is full, the watermaker will be
stopped automatically and the message Tank: Full
will appear. In this condition the system is in pause.
Once the high level sensor switch off (tank no more
totally full) the message AUTO, SYSTEM PAUSE will
appear. It means that the system is in a standby
mode. In this condition the watermaker can be also
restarted manually pushing START.
If not restarted manually, the watermaker will restart
automatically when the level in the tank will be very-
low.
The watermaker can anyway be stopped at anytime pushing STOP.