Interval Timer for Automatic Measurements
Any number of SmartBobs on the network can be configured for an automatic measurement with
a time between measurements ranging from 0 minutes (continuous) to 49 hours and 59 minutes
in 1 minute increments.
Vessel Parameters
Vessel Height in feet:
Vessel Height in meters:
Body Height in feet:
Body Height in meters:
Body Radius/Width in feet:
Body Radius/Width in meters:
Hopper Height in feet:
Hopper Height in meters:
Outlet Radius/Width in feet:
Outlet Radius/Width in meters:
Sensor Offset in feet:
Sensor Offset in meters:
Product Density in lbs/cu ft:
Product Density in kg/cu m:
Displayed Measurement Accuracy
Headroom Height:
Product Height:
Volume / Weight:
4-20mA Output Accuracy
Headroom Height:
Product Height:
Volume / Weight:
Ambient Temperature
Storage:
Operating:
925-0301 Rev C
1.00 to 299.99 in 0.01 increments
0.30 to 89.99 in 0.01 increments
1.00 to 299.99 in 0.01 increments
0.30 to 89.99 in 0.01 increments
0.10 to 59.99 in 0.01 increments
0.10 to 19.99 in 0.01 increments
0.10 to 29.99 in 0.01 increments
0.10 to 8.99 in 0.01 increments
0.10 to 8.99 in 0.01 increments
0.10 to 2.99 in 0.01 increments
-99.99 to 99.99 in 0.01 increments
-29.99 to 29.99 in 0.01 increments
1.00 to 199.99 in 0.01 increments
16.00 to 3,999.99 in 0.01 increments
+/-0.01 of reading plus the accuracy of the SmartBob sensor.
+/-0.01 of reading plus the accuracy of the SmartBob sensor
plus the accuracy of the entered vessel's height.
+/-0.01 of reading plus the accuracy of the SmartBob sensor
plus the accuracy of all entered vessel parameters.
+/-0.16% plus the accuracy of the SmartBob sensor.
+/-0.16% plus the accuracy of the SmartBob sensor plus the
accuracy of the entered vessel's height.
+/-0.16% plus the accuracy of the SmartBob sensor plus the
accuracy of all entered vessel parameters.
-4° to 158° Fahrenheit (-20° to 70° Celsius)
-4° to 158° Fahrenheit (-20° to 70° Celsius)
6