Troubleshooting for Outdoor Unit

7.16 CT or Related Abnormality

H8
Error Code
Outdoor Unit LED
A
Display
Method of Error
A CT or related error is detected by checking the compressor running frequency and CT-detected
input current.
Detection
Error Decision
Conditions
Supposed
Causes
182
j
i
i
h
h
1
2
3
4
The compressor running frequency is more than
A (Hz)
B (A)
55
0.5
If the error repeats, the system is shut down.
Reset condition: Continuous run for about 60 minutes without any other error
Defective power module
Broken or disconnected wiring
Defective reactor
Defective outdoor unit PCB
h
5
Hz and input current is less than
A
SiUS121632EA
A.