Heatilator CRAVE4836-C Installation Manual page 71

Hide thumbs Also See for CRAVE4836-C:
Table of Contents

Advertisement

Four Square and Illusion Decorative Barrier Front
Overlap Fit (0-1 Inch Thick Finishing Material Only)
Non-Combustible Finish Materials
Decorative Barrier Front
Four Square/Illusion
WARNING! Risk of Fire! DO NOT cover rectangular
holes on bottom access panel when installing overlap
fronts.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specified in
this manual. Overlapping materials could ignite.
NOTICE: If one inch maximum finishing material thickness
is exceeded, the decorative barrier front will not fit. This
one inch maximum not only includes the decorative finish
materials (marble, tile, slate, etc) but also the thin set, lath
and adhesive used to attach the decorative finish material.
The non-combustible finishing material, 0-1 inch thick,
should be installed up to the fireplace opening on the top
and sides.
Use the factory-installed top finishing guard to ensure the
finishing material does not extend into the fireplace open-
ing.
Non-combustible finishing material should be installed
on the bottom up to the bottom finishing template. See
Figure 10.9. Do not cover the eight rectangular holes on
the bottom access panel. See Figure 10.10 for minimum
finished opening dimensions.
Figure 10.9 Non-Combustible Finish Material Diagram for 0-1 Inch Thick Overlap Fit Method (Four Square/Illusion)
Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21
Finishing Method
Overlap Fit
WARNING! Risk of Fire! DO NOT apply finishing mate-
rial beyond the top finishing guard and the bottom finish-
ing template. Appliance will overheat if finishing material
extends into appliance opening.
1. Follow instructions provided with decorative barrier
front for installation.
NOTICE: Decorative barrier front will not fit properly if
finishing material is applied beyond the finishing guard.
BOTTOM FINISHING TEMPLATE
BOTTOM PANEL
= RECTANGULAR ACCESS HOLES
DO NOT COVER
Material Thickness
0-1 inch
Trim Ring
Not included