Hide thumbs Also See for CRAVE4836-C:
Table of Contents

Advertisement

CAUTION! Risk of Fire! DO NOT store instruction manuals inside fireplace cavity.
High temperatures could cause a fire.
INSTALLER: Leave this manual with the appliance, not inside the appliance.
CONSUMER: Retain this manual for future reference. Do not store inside the appliance.
NOTICE: DO NOT discard this manual!
Models:
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21
Installation Manual
Installation and Appliance Setup
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and must be installed for
the protection of children and other at-risk
individuals.
Decorative barrier front must be ordered separately at
time of appliance purchase. See Section 3.A.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heatilator CRAVE4836-C

  • Page 1 Decorative barrier front must be ordered separately at appliance is not convertible for use with other time of appliance purchase. See Section 3.A. gases, unless a certified kit is used. Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 2: Table Of Contents

    C. Securing and Leveling the Appliance ....47 D. Installing Non-Combustible Facing Material ..48  = Contains updated information. Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 3: Installation Standard Work Checklist

    _____________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date)  = Contains updated information. 2601-982 Rev. F 11/21 Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 4: Product Specific And Important Safety Information

    (1370 m) above sea level. Please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4500 feet (1370 m). Check with your local gas utility to determine proper orifice size. Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 5: Non-Combustible Materials Specification

    State of California to cause cancer and reproductive harm. For more information go to: www. P65Warnings.ca.gov. Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 6: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 7: Getting Started

    Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified service technician, service agency or your dealer. Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 8: Good Faith Wall Surface

    6 in. MEASUREMENTS FROM TOP EDGE OF THE OPENING APPLIANCE FRONT FACTORY-SUPPLIED NON-COMBUSTIBLE BOARD SHOWN INSTALLED. Figure 2.2 Good Faith Wall Surface Temperatures Above Appliance (CRAVE7260-C/CRAVE7260ST-C/CRAVE8472-C/CRAVE8472ST-C) Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 9 Increase “A” dimension. b. Increase “C” and “E” dimension, however, increasing “B” dimension beyond maximum recommended typically results in higher temperatures. Figure 2.4 Good Faith TV Guidelines Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 10: Tools And Supplies Needed

    • Improper positioning of the logs/media (as applicable) or the glass assembly. • Installation and/or use of any component part not approved by Hearth & Home Technologies. Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 11: Framing And Clearances

    1600 1600 7-1/4 7-1/4 8-9/16 8-9/16 8-7/8 8-7/8 2-3/4 2-3/4 23-3/4 23-3/4 46-3/16 1173 1473 17-1/8 17-1/8 36-5/8 36-5/8 Figure 3.1 Appliance Dimensions - CRAVE4836-C, CRAVE6048-C Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 12 24-1/2 24-1/2 1600 1905 7-1/4 8-9/16 8-9/16 8-7/8 8-7/8 2-3/4 2-3/4 23-3/4 23-3/4 1778 2083 36-1/2 36-1/2 17-1/8 17-1/8 Figure 3.2 Appliance Dimensions - CRAVE7260-C, CRAVE8472-C Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 13 1600 1600 7-1/4 7-1/4 8-9/16 8-9/16 8-7/8 8-7/8 2-3/4 2-3/4 46-3/16 1173 1473 23-3/4 23-3/4 17-1/8 17-1/8 36-1/2 36-1/2 Figure 3.3 Appliance Dimensions - CRAVE4836ST-C, CRAVE6048ST-C Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 14 24-1/2 24-1/2 1600 1905 7-1/4 8-9/16 8-9/16 8-7/8 8-7/8 2-3/4 2-3/4 1778 2083 23-3/4 23-3/4 17-1/4 17-1/4 36-1/2 36-1/2 Figure 3.4 Appliance Dimensions - CRAVE7260ST-C, CRAVE8472ST-C Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 15 The Four Square decorative front has an installed depth of 2-1/8 in. (54 mm), measured from the front of the non-combustible finishing material to the front of the decorative front. Figure 3.5 Four Square (Overlap Fit) Decorative Front Dimensions Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 16 The Illusion decorative front has an installed depth of 2-1/2 in. (64 mm), measured from the front of the non-combustible finishing material to the front of the decorative front. Figure 3.6 Illusion (Overlap Fit) Decorative Front Dimensions Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 17 49-3/16 1249 61-3/16 1554 73-3/16 1859 40-5/16 1024 52-5/16 1329 64-5/16 1634 76-5/16 1938 Figure 3.7 Clean Face Trim Front (Inside Fit) Decorative Barrier Front Dimensions Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 18: Appliance Location And Clearances To Combustibles

    10.17 and CRAVE7260-C Millimeters 2019 1835 2854 10.18. 1880 Inches 84-1/4 124-3/8 35-1/4 18-3/4 CRAVE8472-C Millimeters 2235 2140 3159 2184 Figure 3.8 Appliance Locations: CRAVE-C Single-Sided Models Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 19 17-1/8 CRAVE6048ST-C Millimeters 1530 1219 Inches 72-1/4 17-1/8 CRAVE7260ST-C Millimeters 1835 1219 Inches 84-1/4 17-1/8 CRAVE8472ST-C Millimeters 2140 1219 Figure 3.9 Appliance Locations: CRAVE-C See-Through Models Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 20 Construct platform in accordance with local building codes. ****= For installations with vinyl flooring, see Section 3.E.  Figure 3.10 Clearances to Combustibles-CRAVE4836-C, CRAVE6048-C, CRAVE7260-C, CRAVE8472-C Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 21 Construct platform in accordance with local building codes. ****= For installations with vinyl flooring, see Section 3.E. Figure 3.11 Clearances to Combustibles-CRAVE4836ST-C, CRAVE6048ST-C, CRAVE7260ST-C, CRAVE8472ST-C  Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 22 ** Measurement for without trim kit = 2 in. + additional finishing material thickness. If discharge opening is greater than 3 inches, wire mesh is required. Figure 3.12 Passive Heat Front Discharge Framing Dimensions with Clean Face Finish or Trim Kit Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 23 60-1/2 5-5/8 62-3/8 PHTRIM-60C millimeters 1537 1585 Inches 2-9/16 72-1/2 5-5/8 74-3/8 PHTRIM-72C millimeters 1842 1889 Figure 3.13 Passive Heat Front Discharge - Vent Cover Dimensions Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 24 76-1/2 CRAVE7260-C CRAVE7260ST-C millimeters 1594 1943 1321 Inches 12-1/4 8-3/4 81-1/4 70-1/2 CRAVE8472-C CRAVE8472ST-C millimeters 2064 2413 1791 Figure 3.14 Passive Heat Side Discharge Framing Dimensions Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 25 Wire mesh required for front discharge or open top discharge passive heat installations with discharge opening of 3 inches or greater. Figure 3.15 Passive Heat Minimum Framing Dimensions Open Top Discharge Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 26 1594 1283 1359 1981 74-3/4 50-1/2 96-1/2 3-1/2 CRAVE8472-C PHFR-MCE-72 CRAVE8472ST-C 1899 1283 1829 2451 Figure 3.16 Clearances to Combustibles - Ducted Passive Heat Front Discharge Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 27 3-1/2 CRAVE4836-C CRAVE4836ST-C 1270 1321 1943 PHSI-MCE 10-3/16 76-1/2 3-1/2 CRAVE6048-C CRAVE6048ST-C 1270 1321 1943 Figure 3.17 Clearances to Combustibles - Ducted Passive Heat Side Discharge Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 28: Constructing The Appliance Chase

    Minimum height requirements for an exterior chase on a top-vented appliance are shown in Figure 3.18. Reference Figure 4.5 for additional clearances. Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 29: Floor Protection

    110 °F (based on ambient temperature of 70 °F). Consult the manufacturer’s flooring specifications to ensure compatibility. Figure 3.20 Vinyl Flooring Recommendations Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 30: Termination Location And Vent Information

    Over 20/12 to 21/12 ..........8.0 * H minimum may vary depending on regional snowfall. Refer to local codes. Figure 4.1 Minimum Height From Roof to Lowest Discharge Opening Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 31 • Vinyl protection kits are suggested for use with vinyl siding. • Measure horizontal and vertical termination cap clearances as noted in Figure 4.3. H=Measure Horizontal Distances from H V=Measure Vertical Distances from V Figure 4.3 Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 32: Vent Terminal Clearances

    18 in. (457 mm)* two sides beneath the floor.) Vinyl or composite overhang 42 in. (1067 mm) 42 in. (1067 mm) Figure 4.5 Minimum Clearances for Termination Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 33: Use Of Elbows

    Figure 4.7 Vertical and Horizontal Offset for DVP Elbows DVP48 1219 DVP6A 3 to 6 76 to 152 2-1/8-4-1/4 54-108 DVP12A 3 to 12 76 to 305 2-1/8-8-1/2 54-216 Figure 4.6 Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 34: Vent Diagrams

    (OUTSIDE MOUNTING SURFACE) Figure 4.9 Measure to Outside Mounting Surface 1/4 in. max. (6 mm) Figure 4.8 Figure 4.10 Measure to Top of Last Section of Pipe Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 35 = 63 ft. (19.2 m) Maximum = 63 ft. (19.2 m) Maximum = 24 ft. (7.3 m) Maximum = 24 ft. (7.3 m) Maximum Figure 4.11 Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 36 = 63 ft. (19.2 m) Maximum = 63 ft. (19.2 m) Maximum = 24 ft. (7.3 m) Maximum = 24 ft. (7.3 m) Maximum INSTALLED HORIZONTALLY Figure 4.12 Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 37 = 63 ft. (19.2 m) Maximum = 63 ft. (19.2 m) Maximum = 24 ft. (7.3 m) Maximum = 24 ft. (7.3 m) Maximum Figure 4.13 Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 38 Note: If installing a vertical vent/termination off the top of the appliance, the optional exhaust restrictor may be needed. Note: Use DVP Series components only. Figure 4.14 Vertical Vent Maximum Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 39 NOTICE: Before painting, contact your dealer for information on the appropriate high temperature paint. Figure 4.17 Set the Exhaust Restrictor Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 40 15 ft. 4.6 m = 23 ft. (7.1 m) Maximum Total = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum Total Figure 4.18 Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 41 15 ft. 4.6 m = 23 ft. (7.1 m) Maximum = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum INSTALLED HORIZONTALLY Figure 4.19 Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 42: Vent Clearances And Vent Framing

    1 in. (25 mm) clearance around vertical sections 1 in. (25 mm) clearance Wall bottom & sides Shield Firestop WALL Figure 5.1 Horizontal Venting Clearances To Combustible Materials Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 43: Wall Penetration Framing/Firestops

    Note: Center of the horizontal vent pipe to the vertical measuring surface of a trap cap is 5 inches (127 mm). Figure 5.2 Wall Penetration Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 44: Ceiling Firestop/Floor Penetration Framing

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 5.4 Installing the Attic Shield Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 45: Appliance Preparation

    5. Place the fiberglass rope ring over the gasket. Ensure both the gasket and the rope ring are seated on the top of the appliance. See Figure 6.2 and Figure 6.3. Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 46: Prepare For Heat Management

    MCE): May be used with HEAT-ZONE-GAS or one HEAT-OUT-GAS. The dedicated knockouts must be used only as indicated in Figure 6.4. Figure 6.5 Heat-Zone-Gas Linear Adapter Collar Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 47: Securing And Leveling The Appliance

    FLANGE FLANGE materials and the ceiling clearances are maintained. Figure 6.6 Nailing Tabs Figure 6.7 Nailing Tabs Shipping Position Installation Position Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 48: Installing Non-Combustible Facing Material

    • See Section 10 for finishing materials guidelines. Figure 6.8 Proper Positioning and Securing of an Appliance Figure 6.9 Install Factory-Included Non-Combustible Facing Material Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 49: Venting

    • Only outer pipes need to be sealed. All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed in this manner, unless otherwise stated. Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 50 Figure 7.1 High Temperature Silicone Sealant Lances Lances Figure 7.3 Figure 7.2 Note: Make sure that the seams are not aligned to prevent unintentional disconnection. CORRECT INCORRECT Figure 7.4 Seams Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 51: Assemble Slip Sections

    NOTICE: If slip section is too long, the inner and outer flues of the slip section can be cut to the desired length. Figure 7.8 Securing Horizontal Pipe Sections Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 52: Disassemble Vent Sections

    Figure 7.10. • Pull carefully to separate the pieces of pipe. Figure 7.9 Rotate Seams for Disassembly Figure 7.10 Align and Disassemble Vent Sections Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 53: Vertical Termination Requirements

    • Tighten nut and make sure the collar is tight against the above the roof. pipe section. • Seal around the top of the storm collar. See Figure 7.13. SEAL Figure 7.11 Figure 7.11 Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 54: Horizontal Termination Requirements

    • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Important Notice: Heat shields may not be field constructed. Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 55 Note: When using termination caps with factory-supplied heat shield attached, no additional wall shield firestop is required on the exterior side of a combustible wall. Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 56: Electrical Information

    It is recommended that the fireplace and TV use different circuits to mitigate the interference potential. If interference is occurring on the same circuit, the use of surge protectors may help alleviate the interference. Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 57 LED DIMMER TRAY TRAY SCREW SCREW JUNCTION BOX JUNCTION BOX SCREW SCREW LED POWER SUPPLY LED POWER SUPPLY Figure 8.3 Valve Cavity (Lower Access Panel Removed) Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 58: Wiring Requirements

    Do not store batteries in the battery pack when the appliance is powered by the 6 volt transformer connected to permanent electrical service. Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 59 LED LIGHT TRAY (48 INCH MODELS) 6V DC BATTERY PACK LED LIGHT TRAY (60 INCH MODELS) BROWN LED LIGHT TRAY (72 INCH MODELS) Figure 8.4 IntelliFire Touch Wiring Diagram Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 60: Gas Information

    CAUTION! Risk of Overheating! Component heat shield MUST be installed before operating appliance. Electrical components will be damaged. Figure 9.1 Valve Pressure Taps Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 61 GAS ACCESS Figure 9.5 Gas Fitting Access with Bottom Glass Shield Removed BURNER 48 BURNER 60 BURNER 72 Figure 9.3 Media Tray with Burner and Pilot Shield Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 62: Gas Connection

    Check all fittings and connections with a non-corrosive commercially available leak-check solution. DO NOT use open flame. Fittings and connections could have loos- ened during shipping and handling. Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 63: Air Shutter Setting

    If flames are dark orange with dark, smoky tips, provide more primary air to the burner by opening the air shutter accordingly. DETAIL Figure 9.6 Air Shutter Location Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 64: Finishing

    Passive Heat optional operation. heat management system will also reduce the chances of cracking. Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 65: Drywall Installation

    = NO FASTENERS IN THIS AREA Note: It is acceptable to use a high temperature silicone sealant to adhere drywall to lower cover panel. Figure 10.1 Screw Length Requirements Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 66 Included & Used (Option #2) Clean Face Trim (CFT) Overlap Fit 0-1 inch Included & Used Four Square/Illusion Overlap Fit 0-1 inch Not included Table 1 Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 67 INSIDE FIT = 1-4 IN. THICK INSIDE FIT = 1-4 IN. THICK BOARD FINISHING FINISHING GUARDS GUARDS BOTTOM FINISHING TEMPLATE (Control side only) Figure 10.3 Finishing Materials - See-Through Models Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 68: Decorative Barrier Fronts

    Included & Used 39-1/8 IN.CRAVE4836-C/CRAVE4836ST-C 51-1/8 IN.CRAVE6048-C/CRAVE6048ST-C 63-1/8 IN.CRAVE7260-C/CRAVE7260ST-C 75-1/8 IN.CRAVE8472-C/CRAVE8472ST-C 15-3/4 IN. FIREPLACE VIEWING AREA Figure 10.4 Minimum Finished Opening Dimensions - Clean Face Trim Front Method Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 69 BOTTOM GLASS SHIELD panel. BOTTOM FINISHING TEMPLATE • Overheating and fire could occur. RECTANGULAR HOLE Figure 10.6 Install Shoulder Bolts Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 70 Figure 10.7 Non-Combustible Finish Material Diagram for 1-4 Inch Thick Inside Fit Method Using Trim Ring (Option #2) Figure 10.8 Finishing and Facing Materials - Inside Fit CFT Decorative Barrier Front Only Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 71 BOTTOM FINISHING TEMPLATE BOTTOM PANEL = RECTANGULAR ACCESS HOLES DO NOT COVER Figure 10.9 Non-Combustible Finish Material Diagram for 0-1 Inch Thick Overlap Fit Method (Four Square/Illusion) Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 72 51-1/8 IN.CRAVE6048-C/CRAVE6048ST-C 63-1/8 IN.CRAVE7260-C/CRAVE7260ST-C 17-1/4 IN. FIREPLACE VIEWING AREA Figure 10.10 Minimum Finished Opening Dimensions - Overlap Fit Method (Four Square and Illusion Decorative Barrier Fronts Only) Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 73: Mantel And Wall Projections

    Figure 10.14 Minimum Vertical and Maximum Horizontal Dimensions of Combustibles - CRAVE4836-C, Dimensions of Combustibles - Passive Heat Kit CRAVE4836ST-C, CRAVE6048-C and CRAVE6048ST-C Installed (All Sizes) Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 74 Figure 10.18 Mantel Leg or Wall Projections (Acceptable on both sides of opening) Figure 10.17 Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 75 * Wire mesh required for front discharge or open top discharge passive heat installations with discharge opening of 3 inches or greater. Figure 10.19 Clearances with Passive Heat Optional Heat Management System Installed Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 76: Appliance Setup

    4. Replace bottom glass shield and decorative barrier front. GLASS CLIPS COMPONENT INSULATION COMPONENT INSULATION Figure 11.3 Component Insulation Location BOTTOM RETAINING LIP Figure 11.1 Fixed Glass Assembly Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 77: Clean The Appliance

    Install the log set per instructions included with kit. install one. For more information refer to the instructions supplied with your decorative barrier front. Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 78: Reference Materials

    6 in. 14 IN. (152 mm) (356 MM) 12 IN. (305 MM) DVP-WS (Wall Shield Firestop) DVP-RDS ROOF DECK INSULATION SHIELD Figure 12.1 DVP Vent Components Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 79 79 mm 117 mm Horizontal Termination Cap 5-3/8 in. 9-3/8 in. Trap2 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC1 DVP-HPC2 Figure 12.2 DVP Vent Components Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 80 9-1/2 in. (352 mm) (241 mm) 26 in. 660 mm 14 in. (356 mm) DVP-HSM-B DRC-RADIUS Extended Heat Shield Cap Shield Figure 12.3 DVP Vent Components Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 81 146 to 213 mm 140 mm 213 mm 3° 87° 15 in. (381 mm) 10-1/2 in. 267 mm 10-7/8 in. 276 mm DVP-HRC-SS DVP-HRC-ZC-SS Figure 12.4 DVP Vent Components Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 82 Only use listed decorative termination caps/shrouds with Hearth & Home Technologies approved venting systems. This applies to both DVP and SLP venting systems. Decorative Terminations Caps/Shrouds DTO134 DTO146 DTS134 DTS146 LDS33 LDS46 LDS-BV Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 83 Note: The PVV-SLEEVE-12 and/or PVV-SLEEVE-48 is required to be installed with the PVV-SLP. It is ordered separately from the PVV-SLP. Contact your dealer to order. Figure 12.6 PVV-SLP Vent Components Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 84 102 mm 5-1/16 in. 5-1/16 in. 8-1/8 in. 8 in. (128 mm) 128 mm 206 mm (203 mm) DVP-2SL SL-2DVP Adapter Adapter Figure 12.7 PVI-SLP-B Vent Components Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 85 60 FT PV Wire Harness PVI-WH60 80 FT PV Wire Harness PVI-WH80 100 FT PV Wire Harness PVI-WH100 PVLP-HS PVLP-BEK Heat Shield Brick Kit Figure 12.8 PVLP-SLP Vent Components Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...
  • Page 86: Accessories

    Please contact your Heatilator dealer with any questions or concerns. For the location of your nearest Heatilator dealer, please visit www.heatilator.com. Printed in U.S.A. - Copyright 2021 Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21...

Table of Contents