Heatilator CRAVE4836-C Installation Manual page 24

Hide thumbs Also See for CRAVE4836-C:
Table of Contents

Advertisement

Framing Dimensions - Passive Heat Side Discharge (PH-SIDE) Single-Sided or See-Through
Side Discharge: Air conveyed into the room through two discharge registers,
one on each side of appliance.
E = NON-COMBUSTIBLE ZONE
(BOTH SIDES)
E
APPLIANCE MAY BE INSTALLED
OFF OF FLOOR
Inches
CRAVE4836-C
CRAVE4836ST-C
millimeters
Inches
CRAVE6048-C
CRAVE6048ST-C
millimeters
Inches
CRAVE7260-C
CRAVE7260ST-C
millimeters
Inches
CRAVE8472-C
CRAVE8472ST-C
millimeters
Figure 3.14 Passive Heat Side Discharge Framing Dimensions
24
Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21
B
A
F
D
C
SIDE DISCHARGE FRAMING DIMENSIONS
A
B
Height of
Width of
Discharge
discharge
Opening
Opening
12-1/4
8-3/4
311
222
12-1/4
8-3/4
311
222
12-1/4
8-3/4
311
222
12-1/4
8-3/4
311
222
1-1/2 IN. (2 X 4 FRAMING)
CHASE CEILING ZONE
WARNING! Risk of Fire! DO NOT place
combustible objects or combustible materials
in non-combustible zone. Appliance and
combustible materials will overheat.
C
D
Minimum
Clearance
Minimum
Bottom of
Clearance
Appliance
Bottom of
to Bottom of
Appliance
Discharge
to Ceiling
Opening
62-3/4
76-1/2
1594
1943
62-3/4
76-1/2
1594
1943
62-3/4
76-1/2
1594
1943
81-1/4
95
2064
2413
ROOM CEILING
CHASE CEILING (REQUIRED)
DISCHARGE OPENING
= PASSIVE HEAT
DISCHARGE OPENING
E
F
Minimum
Minimum
Clearance
Clearance to
Appliance
Combustible
Opening to
Materials
Ceiling
18
52
457
1321
18
52
457
1321
18
52
457
1321
18
70-1/2
457
1791