3-1. SPECIFICATIONS
MUY-GE24NA
Model name
Capacity
Rated (Minimum~Maximum)
Power consumption
Rated
(Minimum~Maximum)
EER
[SEER] 3
1
Power supply
Max. fuse size (time delay)
Min. circuit ampacity
Fan Motor (ECM)
Compressor
Refrigerant control
Sound level 1
Defrost method
Dimensions
Weight
External finish
Remote controller
Control voltage (by built-in transformer)
Refrigerant piping
Refrigerant pipe size
(Min. wall thickness)
Connection method
Between the indoor & out-
door units
Refrigerant charge (R410A)
NOTE: Test conditions are based on ARI 210/240.
1: Rating conditions (Cooling) — Indoor: 80˚FDB, 67˚FWB, Outdoor: 95˚FDB, (75˚FWB)
(Heating) — Indoor: 70˚FDB, 60˚FWB, Outdoor: 47˚FDB, 43˚FWB
2:
(Heating) — Indoor: 70˚FDB, 60˚FWB, Outdoor: 17˚FDB, 15˚FWB
Due to continuing improvement, above specification may be subject to change without notice.
MSY-GE-10
M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014)
Cooling 1
Btu/h
Cooling 1
W
Cooling
V , phase , Hz
A
A
F.L.A
Model
R.L.A
L.R.A
Fl.Oz.
Refrigeration oil
(Type)
Cooling
dB(A)
W
in.
D
in.
H
in.
Ib.
VDC
Liquid
in.
Gas
in.
Indoor
Outdoor
Height difference
ft.
Piping length
ft.
MUY-GE24NA
22,500
( 8,200 ~ 31,400 )
1,800 (570 ~ 3,580)
12.5 [19.0]
208/230 , 1 , 60
20
17.1
0.93
SNB172FQKMT
12.9
16.1
29.4 (FV50S)
Linear expansion valve
55
Reverse Cycle
33-1/16
13
34-5/8
119
Munsell 3Y 7.8/1.1
Wireless type
12 - 24
Not supplied
3/8 (0.0315)
5/8 (0.0315)
Flared
Flared
50
100
4 lb. 3 oz.
Rated frequency
Rated frequency
Maximum frequency
© 2014 Mitsubishi Electric US, Inc.