Changing The Oil And Oil Filter; Servicing The Air Cleaner - Generac Power Systems 9 kW Owner's Manual

60 hz air-cooled generators 9kw to 22kw
Hide thumbs Also See for 9 kW:
Table of Contents

Advertisement

Maintenance

Changing the Oil and Oil Filter

Proceed as follows to change the oil and oil filter:
1. Press the MANUAL button on the control panel to
start the engine, and run it until it is thoroughly
warmed up. Press the control panel OFF button to
shut down the engine.
2. See
Figure 4-2
or
the engine stops, and when it has cooled slightly,
lift the lid and remove the front panel. Pull the oil
drain hose (A) free of its retaining clip. Remove the
cap from the hose and drain the oil into a suitable
container.
Figure 4-2. Oil Filter and Drain Location (9 kW)
B
A
Figure 4-3. Oil Filter and Drain Location (11-22 kW)
3. Replace the cap after the oil has drained.
Reposition and secure the hose with the retaining
clip.
4. Remove the old oil filter (B) by turning it
counterclockwise.
5. Apply a light coating of clean engine oil to the
gasket of the new filter.
6. Screw the new filter on by hand until its gasket
lightly contacts the oil filter adapter. Tighten the
filter an additional 3/4 to one full turn.
7. Refill the engine with the proper recommended oil.
See
Engine Oil
Requirements.
26
Figure
4-3. A few minutes after
B
A
8. Press the MANUAL button on the control panel to
start the engine, run for one minute, and check for
leaks.
9. Press the OFF button on the control panel to stop
the engine. Wait five minutes.
10. Recheck the oil level. Add oil as needed. DO NOT
OVERFILL.
11. Reinsert oil dipstick and/or reattach fill cap.
12. To return the unit to AUTO mode, press the control
panel AUTO button.
13. Dispose of the used oil and filter at a proper
collection center.

Servicing the Air Cleaner

Proceed as follows to service the air cleaner:
1. Press the OFF button on the control panel to stop the
generator. Then lift the lid and remove the front panel.
2. See
Figure 4-4
clips (A) and air cleaner cover (B).
.
001831
Figure 4-4. Servicing Air Cleaner (9 kW)
B
001799
A
C
Figure 4-5. Servicing Air Cleaner (11-22 kW)
3. Remove the old air filter element (C) and discard.
4. Thoroughly clean the air cleaner enclosure of any
dust or debris.
5. Install a new air filter element.
6. Install the air cleaner cover and fasten the cover clips.
Owner's Manual for 60 Hz Air-Cooled Generators
or
Figure
4-5. Remove the cover
C
Continued on next page.
A
B
001820
D
001814

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

11 kw16 kw20 kw22 kw

Table of Contents