Cr Scale - Epson Stylus PHOTO RX600 Service Manual

Hide thumbs Also See for Stylus PHOTO RX600:
Table of Contents

Advertisement

EPSON Stylus PHOTO RX600/610, RX620/630

4.5.1 CR Scale

When handling the CR scale, hold both ends, or top and bottom
C A U T I O N
only. Do not touch the reading surface. Pay attention to keeping out
of stains or scratches on the reading surface.
1.
Middle Housing Removal. (p43)
2.
Unhook a extension spring to the CR scale on the left side of the printer.
3.
Remove the CR scale from the printer frame on the right side of the printer.
4.
Pull out the CR scale from the carriage unit to the left.
5.
Turn the CR scale to 90 degrees, and remove it along with a pull spring.
Pass the CR scale through the CR encoder located on back of the
carriage unit.
Rear view
Disassembly and Assembly
CR Encoder
CR Scale
Disassembly and Assembly of Printer Unit
Extension Spring,
CR Scale
Figure 4-9. CR scale Removal