Electrical Wiring Diagrams - Waterstage Comfort 5 Installation And Operating Manual

Air to water heat pump, split system: outdoor unit, hydraulic unit
Table of Contents

Advertisement

Air to Water Heat Pump

5 Electrical wiring diagrams

Electronic expansion valve
Temperature sensors
Temperature sensors
Temperature sensors
Temperature sensors
Terminal
block
1
Interconnection
between the outside unit
and the hydraulic module
figure 36 - Electrical wiring of outdoor unit model alféa excellia (single phase type)
- 50 -
Reactor
Reactor
OR
W10
W11
BK
1
1
2 CN72
BK
2
Evaporator
BK
1
1
BK
2
2
BN
3
3
Discharge
BN
4
4
Outdoor
BK
1
1
2
2
BK
3
3
BK
W1
WH
W2
RD
W20
Fuse 250V 20A
BK
W16
WH
W12
GN
W3
2
3
L
N
(N)
Electricity supply
WOYA 060 LDC
W7
W8
W9
1
CN73
2
3 3
1
2
3
CN39
CN71
4
5
6
Regulation
7
8
board
1
2
CN70
3
CN800
4
5
6
7 7
1
2
3
CN401
4
5
1
CN30
2
3
Waterstage Comfort 5 & 6
R
RD
Compressor
WH
C M
S
BK
C
BK
Compressor
1
2
Temperature sensors
BK
RD
RD
1
1
1
Pressure
WH
WH
2
PS
2
2
Sensor
BK
3
3
3
BK
4
RD
1
2
3
BK
Ventilator
4
F M
WH
5
YE
6
BN
RD
1
BU
2
Electronic
OG
3
PMV
expansion valve
YE
4
WH
5
BK
1
4-way valve
4WV
2
BK
3
Installation and operating manual "1532 - EN"
Color Codes
BK Black
BN Brown
BU Blue
GN Green
GY Grey
OG Orange
RD Red
VT Purple
WH White
YE Yellow

Advertisement