Air to Water Heat Pump
Line
Function
Heating, circuit 2
Only with the 2nd circuit kit option (If the installation consists of 2 heating circuits).
1010
U
Comfort setpoint
1012
U
Reduced setpoint
1014
U
Frost protection setpoint
1016
S
Comfort setpoint maximum
1020
I
Heating curve slope
I
1021
Heating curve displacement
1026
I
Heating curve adaption
Warning ! Not to modify, let on "Off".
1030
I
Summer / Winter heating limits
When the average of the outside temperatures over the past 24 hours reaches 18°C, the regulator switches off the heating
(as an economy measure). During summer mode, the display shows "Eco". This function is only active in automatic mode.
S
1032
24-hour heating limit
This function enables you partially to offset the automatic summer/winter switchover during the intermediate seasons.
Increasing the value delays the switchover to summer regime.
Decreasing the value advances the switchover to summer regime.
This function is only active in automatic mode.
1040
I
Flow temp setpoint min (for fan convector)
1041
I
Flow temp setpoint max
Floor heating system = 50 °C / Radiators = 65 °C.
Important Note : Maximum temperature limitation is not a safety function as required by ground heating.
S
1050
Room influence
If the installation is fitted with a room thermostat:
This function enables you to choose the ambient temperature's influence on the setting.
If no value is entered, the setting is made based on the temperature control.
If the parameter is set at 100%, the setting is only based on the ambient temperature.
1080
S
Quick setback
1090
S
Optimum start control max
1091
S
Optimum stop control max
1100
S
Reduced setpoint increase start
S
1101
Reduced setpoint increase end
1130
S
Mixer valve increase
1134
S
Actuator running time
1150
I
Floor curing function
- Off: Early interruption of the current program, program inactive.
- Functional heating.
- Heating ready for occupation.
- Functional heating + Curing heating.
- Curing heating + Functional heating.
- Manually: Manual mode enables you to programme your own concrete slab drying time.The function ends
automatically after 25 days.
1151
I
Floor curing setpoint manually
(if line 1150 = manual)
This function enables you to set the custom concrete slab drying temperature. This temperature remains fixed.
The concrete slab-drying program stops automatically after running for 25 days.
1156
I
Floor curing day current
1157
I
Floor curing day completed
- 40 -
(figure 32, page
35)
(figure 33, page
35)
(figure 35, page
39)
Setting range
or display
Reduced setpoint...
Comfort setpoint maximum
Frost protection setpoint...
Comfort setpoint
4 °C... Reduced setpoint
Comfort temp... 35 °C
0,1... 4
-4,5... 4,5 °C
Off, On
8
30 °C
-10... 10 °C
8
70 °C
8
70 °C
1 %... 100 %
Off, Down to reduced setpoint,
Down to frost prot setpoint
0... 360 min
0... 360 min
-30... 10 °C, --°C
-30... 10 °C, --°C
0
50 °C
30... 873 s
0
95 °C
0
32
0
32
Installation and operating manual "1532 - EN"
Setting
Basic
increment
setting
0,5 °C
20 °C
0,5 °C
19 °C
0,5 °C
8 °C
1 °C
28 °C
0,02
0,5
0 °C
0,5 °C
Off
0,5 °C
18 °C
-2 °C
1 °C
1 °C
8 °C
1 °C
55 °C
50 %
1 %
Down to
reduced
setpoint
10 min
180 min
10 min
60 min
1 °C
--
-5 °C
1 °C
1 °C
0 °C
1 s
240 s
Off
1 °C
25 °C
0