Toshiba MMK-AP0057HP-E Service Manual page 107

Mult type air-conditioner, high wall types
Hide thumbs Also See for MMK-AP0057HP-E:
Table of Contents

Advertisement

No.
Part name
TC2 sensor
Procedures
5) Pull out TC1, TC2, TCJ sensors from sensor
holder of hear exchanger.
(Pay attention to mounting positions of each
sensor when reassembling of electric parts. Be
sure to apply marking, etc to TC2 and TCJ
sensors before removing because their shapes
are reassembled.)
TC1 sensor
6) Remove the earth screw and earth line from
evaporator.
7) Disconnect the connectors for the fan motor,
louver motor and PMV motor from P.C. board
assembly.
8) Remove the 2 fixing screws that secures the
electric parts box assembly, unit display
assembly and remove the electric parts box
assembly.
TCJ sensor
- 107 -
FILE NO. SVM-17045
Remarks
Earth screw
Electric parts box
Screw
Screw
Unit display

Advertisement