L09
L10
L10
L20
L28
L28
01: IPDU1 error
02: IPDU2 error
03: IPDU3 error
L29
L29
04: Fan IPDU error
05: IPDU1 + Fan IPDU error
06: IPDU2 + Fan IPDU error
07: All IPDU error
L30
L30 Detected indoor address
L31
P01
P03
P03
01: Comp. 1 side
P04
P04
02: Comp. 2 side
01: Phase-missing detection
P05
P05
02: Phase error
01: Comp. 1 side
P07
P07
02: Comp. 2 side
P10
P10 Detected indoor address
P12
P13
P13
01: TS condition
P15
P15
02: TD condition
P17
P17
P19
P19 Detected outdoor unit number
P20
P20
0
1
3
P22
P22
C
D
E
01: Comp. 1 side
P26
P26
02: Comp. 2 side
P29 01: Comp. 1 side
P29
02: Comp. 2 side
P31
P31
Error detected by TCC-LINK central control device
Check code
Central
Outdoor 7-segment display
control
device
indication
C05
C06
C12
Differs according to error contents of unit with occurrence of alarm Group control branching unit error
P30
TCC-LINK: TOSHIBA Carrier Communication Link.
1111058602_EN.indd 35
: IGBT short
: Fan motor position
detective circuit error
: Fan motor trouble
: TH sensor temp. error
(Heat sink overheat)
: TH sensor error
: Vdc output error
By alarm device ALT
Wireless remote controller
Sensor block display of
Auxiliary code
OPERATION TIMER PRE.DEF. Flash
(L20 is displayed.)
SIM
Indoor capacity unset
SIM
Outdoor capacity unset
SIM
Duplicated central control addresses
SIM
Over No. of connected outdoor units
SIM
No. of IPDU error
SIM
Indoor outside interlock
Extended I/C error
ALT
Indoor fan motor error
ALT
Discharge temp. TD1 error
ALT
High-pressure SW system operation
ALT
Phase-missing detection /Phase error
ALT
Heat sink overheat error
ALT
Indoor overflow error
ALT
Indoor fan motor error
ALT
Outdoor liquid back detection error
ALT
Gas leak detection
ALT
Discharge temp. TD2 error
ALT
4-way valve inverse error
ALT
High-pressure protective operation
ALT
Outdoor fan IPDU error
ALT
G-TR short protection error
Comp position detective circuit system
ALT
error
Other indoor unit error
ALT
(Group terminal unit error)
Error in indoor group
receiving unit
Sending error in TCC-LINK central
control device
Receiving error in TCC-LINK central
control device
Batch alarm of general-purpose
equipment control interface
Duplicated central control addresses
- 102 -
FILE NO. SVM-17045
Installation Manual
AI-NET,
IPDU, I/F
AI-NET
Judging
Check code name
device
TCC-LINK
TCC-LINK
General-
purpose
equipment I/F
TCC-LINK
Indoor
I/F
Indoor
I/F
I/F
Indoor
I/F
Indoor
I/F
IPDU
I/F
Indoor
Indoor
I/F
I/F
I/F
I/F
I/F
IPDU
IPDU
IPDU
Indoor