Wiring Diagram - Mitsubishi Electric PUHZ-ZRP35VKA Service Manual

Hide thumbs Also See for PUHZ-ZRP35VKA:
Table of Contents

Advertisement

8

WIRING DIAGRAM

PUHZ-ZRP35VKA
SYMBOL
NAME
TB1
Terminal Block < Power Supply, Indoor/Outdoor>
MC
Motor for Compressor
MF1
Fan Motor
21S4
Solenoid Valve (Four-Way Valve)
63H
High Pressure Switch
TH3, TH33
Thermistor <Outdoor Pipe >
TH4
Thermistor < Discharge>
TH6
Thermistor < Outdoor 2-Phase Pipe>
TH7
Thermistor < Outdoor>
TH8
Thermistor < Heat Sink>
TH32
Thermistor < Comp. surface>
LEV-A, LEV-B
Electronic Expansion Valve
ACL
Reactor
C. B.
Controller Circuit Board
LD-U
Lead Wire <U-Phase >
LD-V
Lead Wire <V-Phase >
LD-W
Lead Wire <W-Phase >
LD-LI
Lead Wire <L-Phase >
LD-NI
Lead Wire <N-Phase >
LD-R0/S0, LD-R/L
Lead Wire <L-Phase(Reactor) >
LD-S1, LD-S2, LD-S3
Lead Wire <Indoor/Outdoor >
LD-EI, LD-E2, LD-E3
Lead Wire <Ground >
DS1, DS2
Diode Bridge
IPM
Power Module
Q1
IGBT
Main Smoothing Capacitor
CB1, CB2
*
1. MODEL SELECT
The black square ( ) indicates a switch position.
MODEL
SW6
ON
35V
OFF
1 2 3 4 5 6 7 8
ON
50V
OFF
1 2 3 4 5 6 7 8
*
2. SW5 -1 to 5 : Function Switch
21S4
C. B.
1
1
MC
U
RED
LD-U
MS
V
WHT
LD-V
3~
LD-W
W
BLK
3
3
IPM
CB2
CB1
Q1
M-NET ADAPTER
SYMBOL
NAME
TB7
Terminal Block <M-net connection>
CN5
Connector <Transmission>
CND
Connector <Power Supply>
CN2M
Connector <M-NET communication>
OCH527B
PUHZ-ZRP50VKA
SYMBOL
F1, F2
F3, F4
52C
RS1
LED1, LED2 LED <Operation Inspection Indicators >
X52
CNMNT
CNVMNT
CNDM
CN51
CNSW
S. B.
SW1
SW4
SW5
SW6
SW7
SW8
SWP
CN31
CNM
CNSW
*
SW5-6
2
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
63H
MF1
TH8
TH33
TH32
TH7 TH6 TH3 TH4
MS
3~
1
1
2
7
1
3
1
2
1
4
CNF1
TH33
CN3
TH32
TH7/6
(WHT)
(YLW)
(WHT)
(BLK)
(RED)
LED1
1
3
63H
(YLW)
LED2
X52
1
3
21S4
(GRN)
RS1
DS1
LD-E3
52C
DS2
LD-R/L
LD-R0/S0
ACL
NAME
Fuse <10A >
Fuse <3.15A >
Relay
Resistor
Relay
Connector
<Connected to Optional M-NET Adapter Board >
Connector
<Connected to Optional M-NET Adapter Board >
Connector <Connected for Option (Contact Input) >
Connector <Connection for Option >
Connector <Connection for Switch Board >
Switch Board
Switch <Forced Defrost, Defect History
Record Reset, Refrigerant Address >
Switch <Test Operation >
Switch <Function Switch >
Switch <Model Select >
Switch <Function Setup >
Switch <Function Setup >
Switch <Pump Down >
Connector <Emergency Operation >
Connector <A-Control Service Inspection Kit >
Connector <Connector for Controller Board >
LEV-A
LEV-B
M
M
1
1
6
1
6
1
2
2 1
CN51
LEV-A
LEV-B
TH3
TH4
(WHT)
(WHT)
(RED)
(WHT)
(WHT)
5
3
1
5
1
3
CNMNT
CNVMNT
(WHT)
(WHT)
LD-S3
LD-S2
LD-S1
F4
F3
F2
F1
LD-E2
LD-EI
16
When M-NET adapter is connected
5
5
1
M-NET ADAPTER
2
1
A B S
TB7
M-NET
S. B.
14
5
1
3
CNDM
(WHT)
6
1
11
2
12
1
6
11
12
CNSW
(WHT)
6
1
2
6
BRN
ORN
YLW
LD-LI
RED
LD-NI
WHT
L
N
POWER SUPPLY
~/N 230V 50Hz
CND
(WHT)
3
1
3
CN31
*
1
*
1
S1 S2 S3
TB1
INDOOR
UNIT