Mitsubishi Electric PUHZ-ZRP35VKA Service Manual page 112

Hide thumbs Also See for PUHZ-ZRP35VKA:
Table of Contents

Advertisement

Request content
Error history 1 (latest)
103
104
Error history 2 (second to last)
Error history 3 (third to last)
105
Abnormal thermistor display
106
(TH3/TH6/TH7/TH8)
107
Operation mode at time of error
Compressor-Operating current at time of error
108
109
Compressor-Accumulated operating time at time of error
110
Compressor-Number of operation times at time of error
Discharge temperature at time of error
111
112
Outdoor unit - Liquid pipe 1 temperature (TH3) at time of error
113
Outdoor unit - Liquid pipe 2 temperature at time of error
Outdoor unit-2-phase pipe temperature (TH6) at time of error
114
115
116
Outdoor unit-Outside air temperature (TH7) at time of error
117
Outdoor unit-Heatsink temperature (TH8) at time of error
118
Discharge superheat (SHd) at time of error
119
Sub-cool (SC) at time of error
120
Compressor-Operating frequency at time of error
Outdoor unit at time of error
121
• Fan output step
Outdoor unit at time of error
122
• Fan 1 speed (Only for air conditioners with DC fan)
Outdoor unit at time of error
123
• Fan 2 speed (Only for air conditioners with DC fan)
124
125
LEV (A) opening at time of error
126
LEV (B) opening at time of error
127
128
129
Thermostat ON time until operation stops due to error
130
131
132
Indoor - Liquid pipe temperature at time of error
133
Indoor - Cond/Eva. pipe temperature at time of error
Indoor at time of error
134
• Intake air temperature <Thermostat judge temperature>
135
136
137
138
139
140
~
146
147
148
149
Indoor - Actual intake air temperature
150
151
Indoor - Liquid pipe temperature
152
Indoor - Cond/Eva. pipe temperature
OCH527B
Description
(Display range)
Displays error history. (" - - " is displayed if no history is present.)
Displays error history. (" - - " is displayed if no history is present.)
Displays error history. (" - - " is displayed if no history is present.)
3
: TH3
6 : TH6
7 : TH7
8 : TH8
0 : No thermistor error
Displayed in the same way as request code "0".
0 – 50
0 – 9999
0 – 9999
3 – 217
-40 – 90
-40 – 90
-39 – 88
-39 – 88
-40 – 200
0 – 255
0 – 130
0 – 255
0 – 10
0 – 9999
0 – 9999
0 – 500
0 – 500
0 – 999
-39 – 88
-39 – 88
-39 – 88
-39 – 88
-39 – 88
-39 – 88
112
Unit
Remarks
Code
Code
Code
Sensor
number
A
10 hours
100 times
Hz
Step
rpm
"0" is displayed if the air conditioner is a single-
rpm
fan type.
Pulses
Pulses
Minutes
Average value of all indoor units is displayed if the air condi-
tioner consists of 2 or more indoor units (twin, triple, quad).
Average value of all indoor units is displayed if the air condi-
tioner consists of 2 or more indoor units (twin, triple, quad).