Ordering Code - Brainchild BTC-2500 User Manual

Self-tune fuzzy/pid process /temperature controller
Table of Contents

Advertisement

1 2 Ordering Code

1 2 Ordering Code
BTC-2500-
Power Input
Power Input
4: 90 - 264 VAC, 47-63 HZ
4: 90 - 264 VAC, 47-63 HZ
5: 11 - 26 VAC or VDC,
5: 11 - 26 VAC or VDC,
SELV, Limited Energy
SELV, Limited Energy
Signal Input
Signal Input
1: Standard Input
1: Standard Input
Input 1 - Universal Input
Input 1 - Universal Input
Thermocouple: J, K, T, E, B,
Thermocouple: J, K, T, E, B,
RTD: PT100 DIN, PT100 JIS
RTD: PT100 DIN, PT100 JIS
Current: 4 - 20mA, 0 - 20 mA.
Current: 4 - 20mA, 0 - 20 mA.
Voltage: 0 - 1V, 0 - 5V, 1 - 5V,
Voltage: 0 - 1V, 0 - 5V, 1 - 5V,
0 - 10V
0 - 10V
Input 2 -
Input 2 -
**
CT: 0 - 50 Amp. AC Current
CT: 0 - 50 Amp. AC Current
Transformer
Transformer
Voltage Input: 0 - 1V, 0 - 5V,
Voltage Input: 0 - 1V, 0 - 5V,
1 - 5V, 0 - 10V.
1 - 5V, 0 - 10V.
Event Input ( EI )
Event Input ( EI )
9: Special Order
9: Special Order
Example
BTC-2500-411111
BTC-2500-411111
90 - 264 operating voltage
90 - 264 operating voltage
Input: Standard Input
Input: Standard Input
Output 1: Relay
Output 1: Relay
Output 2: Relay
Output 2: Relay
Alarm 1: 5V Logic Output
Alarm 1: 5V Logic Output
RS- 485 Communication Interface
RS- 485 Communication Interface
Accessories
CT94-1 = 0 - 50 Amp. AC Current Transformer
CT94-1 = 0 - 50 Amp. AC Current Transformer
OM95-3 = Isolated 4 - 20 mA / 0 - 20 mA Analog Output Module
OM95-3 = Isolated 4 - 20 mA / 0 - 20 mA Analog Output Module
OM95-4 = Isolated 1 - 5V / 0 - 5V Analog Output Module
OM95-4 = Isolated 1 - 5V / 0 - 5V Analog Output Module
OM95-5 = Isolated 0 - 10V Analog Output Module
OM95-5 = Isolated 0 - 10V Analog Output Module
OM94-6 = Isolated 1A / 240VAC Triac Output Module ( SSR )
OM94-6 = Isolated 1A / 240VAC Triac Output Module ( SSR )
OM94-7 = 14V/40mA SSR Drive Module
OM94-7 = 14V/40mA SSR Drive Module
DC94-1 = Isolated 20V / 25mA DC Output Power Supply
DC94-1 = Isolated 20V / 25mA DC Output Power Supply
DC94-2 = Isolated 12V / 40mA DC Output Power Supply
DC94-2 = Isolated 12V / 40mA DC Output Power Supply
DC94-3 = Isolated 5V / 80mA DC Output Power Supply
DC94-3 = Isolated 5V / 80mA DC Output Power Supply
CM94-1 = Isolated RS-485 Interface Module
CM94-1 = Isolated RS-485 Interface Module
CM94-2 = Isolated RS-232 Interface Module
CM94-2 = Isolated RS-232 Interface Module
CM94-3 = Isolated 4 - 20 mA / 0 - 20 mA Retransmission Module
CM94-3 = Isolated 4 - 20 mA / 0 - 20 mA Retransmission Module
CM94-4 = Isolated 1 - 5V / 0 - 5V Retransmission Module
CM94-4 = Isolated 1 - 5V / 0 - 5V Retransmission Module
CM94-5 = Isolated 0 - 10V Retransmission Module
CM94-5 = Isolated 0 - 10V Retransmission Module
CC94-1 = RS-232 Interface Cable (2M)
CC94-1 = RS-232 Interface Cable (2M)
CC91-3 = Programming Port Cable
CC91-3 = Programming Port Cable
1
2
3
R, S, N, L
R, S, N, L
Output 1
Output 1
0: None
0: None
1: Relay rated 2A/240VAC
1: Relay rated 2A/240VAC
2: Pulsed voltage to
2: Pulsed voltage to
drive SSR, 5V/30mA
drive SSR, 5V/30mA
3: Isolated
3: Isolated
***
4 - 20mA / 0 - 20mA
4 - 20mA / 0 - 20mA
4: Isolated 1 - 5V / 0 - 5V
4: Isolated 1 - 5V / 0 - 5V
5: Isolated 0 - 10V
5: Isolated 0 - 10V
6: Triac Output
6: Triac Output
1A / 240VAC,SSR
1A / 240VAC,SSR
C: Pulsed voltage to
C: Pulsed voltage to
drive SSR, 14V/40mA
drive SSR, 14V/40mA
9: Special order
9: Special order
4
5
Alarm 1
Alarm 1
1: 5V Logic
1: 5V Logic
Output
Output
9: Special order
9: Special order
Output 2 / Alarm 2
Output 2 / Alarm 2
0: None
0: None
1: Form A Relay 2A/240VAC
1: Form A Relay 2A/240VAC
2: Pulsed voltage to
2: Pulsed voltage to
*
3: Isolated 4 - 20mA / 0 - 20mA
3: Isolated 4 - 20mA / 0 - 20mA
*
4: Isolated 1 - 5V / 0 - 5V
4: Isolated 1 - 5V / 0 - 5V
5: Isolated 0 - 10V
5: Isolated 0 - 10V
6: Triac Output, 1A / 240VAC, SSR
6: Triac Output, 1A / 240VAC, SSR
7: Isolated 20V / 25mA DC
7: Isolated 20V / 25mA DC
8: Isolated 12V / 40 mA DC
8: Isolated 12V / 40 mA DC
9: Isolated 5V / 80mA DC
9: Isolated 5V / 80mA DC
C: Pulsed voltage to
C: Pulsed voltage to
A: Special order
A: Special order
Range set by front keyboard
Range set by front keyboard
*
Alternative between RS-232 and Input 2
Alternative between RS-232 and Input 2
**
Need to order an accessory CT94-1 if
Need to order an accessory CT94-1 if
***
Heater Break detection is required.
Heater Break detection is required.
Related Products
Related Products
SNA10A = Smart Network Adaptor for Third
SNA10A = Smart Network Adaptor for Third
SNA12A = Smart Network Adapter for
SNA12A = Smart Network Adapter for
BC-Set = Configuration Software
BC-Set = Configuration Software
Communicator = PC software to communicate
Communicator = PC software to communicate
UM25001H
6
Communications
0: None
0: None
1: RS-485
1: RS-485
**
2: RS-232
2: RS-232
3: Retransmit 4-20mA/0-20mA
3: Retransmit 4-20mA/0-20mA
4: Retransmit 1 - 5V / 0 - 5V
4: Retransmit 1 - 5V / 0 - 5V
5: Retransmit 0 - 10V
5: Retransmit 0 - 10V
9: Special order
9: Special order
drive SSR, 5V / 30mA
drive SSR, 5V / 30mA
*
Output Power Supply
Output Power Supply
Output Power Supply
Output Power Supply
Output Power Supply
Output Power Supply
drive SSR, 14V/40mA
drive SSR, 14V/40mA
Party Software, Converts 255
Party Software, Converts 255
channels of RS-485 or RS-422 to
channels of RS-485 or RS-422 to
RS-232 Network
RS-232 Network
programming port to RS-232
programming port to RS-232
interface
interface
1024 tags
1024 tags
*
*
*
7

Hide quick links: