3 3 Rearrange User Menu

3 3 Rearrange User Menu
The conventional controllers are designed with a fixed parameters' scrolling. If
The conventional controllers are designed with a fixed parameters' scrolling. If
you need a more friendly operation to suit your application, the manufacturer
you need a more friendly operation to suit your application, the manufacturer
will say " sorry " to you. The BTC-2500 has the flexibility for you to select those
will say " sorry " to you. The BTC-2500 has the flexibility for you to select those
parameters which are most significant to you and put these parameters in the
parameters which are most significant to you and put these parameters in the
front of display sequence.
front of display sequence.
SEL1 : Selects the most significant parameter for view and change.
SEL1 : Selects the most significant parameter for view and change.
SEL2 : Selects the 2'nd significant parameter for view and change.
SEL2 : Selects the 2'nd significant parameter for view and change.
SEL3 : Selects the 3'rd significant parameter for view and change.
SEL3 : Selects the 3'rd significant parameter for view and change.
SEL4 : Selects the 4'th significant parameter for view and change.
SEL4 : Selects the 4'th significant parameter for view and change.
SEL5 : Selects the 5'th significant parameter for view and change.
SEL5 : Selects the 5'th significant parameter for view and change.
Range : NONE, TIME, A1.SP , A1.DV, A2.SP , A2.DV, RAMP , OFST,
Range : NONE, TIME, A1.SP , A1.DV, A2.SP , A2.DV, RAMP , OFST,
REFC, SHIF, PB1, TI1, TD1, C.PB, DB, SP2, PB2, TI2, TD2
REFC, SHIF, PB1, TI1, TD1, C.PB, DB, SP2, PB2, TI2, TD2
When using the up-down key to select the parameters, you may not obtain
When using the up-down key to select the parameters, you may not obtain
all of the above parameters. The number of visible parameters is dependent
all of the above parameters. The number of visible parameters is dependent
on the setup condition. The hidden parameters for the specific application are
on the setup condition. The hidden parameters for the specific application are
also deleted from the SEL selection.
also deleted from the SEL selection.
Example :
Example :
A1FN selects TIMR
A1FN selects TIMR
A2FN selects DE.HI
A2FN selects DE.HI
PB1 = 10
PB1 = 10
TI1 = 0
TI1 = 0
SEL1 selects TIME
SEL1 selects TIME
SEL2 selects A2.DV
SEL2 selects A2.DV
SEL3 selects OFST
SEL3 selects OFST
SEL4 selects PB1
SEL4 selects PB1
SEL5 selects NONE
SEL5 selects NONE
Now, the upper display scrolling becomes :
Now, the upper display scrolling becomes :
PV

3 4 Display SV Instead of PV

3 4 Display SV Instead of PV
In certain applications where set point value (SV) is more important than
In certain applications where set point value (SV) is more important than
process value (PV) for the user, the parameter
process value (PV) for the user, the parameter
be used to achieve this purpose.
be used to achieve this purpose.
Press
Press
keys to enter setup menu
keys to enter setup menu
until
until
appears on the display. If you need the process value to be
appears on the display. If you need the process value to be
displayed, then select
displayed, then select
point value instead of process value to be displayed, then select
point value instead of process value to be displayed, then select
DISF. Also refer to the flow chart in
DISF. Also refer to the flow chart in
42
DISF
DISF
( display format ) then can
( display format ) then can
, then press
, then press
by using
by using
or
or
key for DISF, If you need set
key for DISF, If you need set
Section 1-5
Section 1-5
to see the location of DISF.
to see the location of DISF.
UM25001D
several times
several times
for
for
SEL1
SEL2
SEL3
SEL4
SEL5
DISF
has two values:
Display process
value
Display set point
value