Appliance Break-In; Heat Management; Detailed Component Operating Instructions - Outdoor Lifestyles TWILIGHT-II-C Owner's Manual

Care and operation
Hide thumbs Also See for TWILIGHT-II-C:
Table of Contents

Advertisement

G. Appliance Break-In
Initial Break-in Procedure
• The fireplace should be run three to four hours
continuously on high.
• Turn the fireplace off and allow it to completely cool.
• Remove fixed glass assembly. See Section 4.
• Clean fixed glass assembly. See Section 4.
• Replace the fixed glass assembly and run continuously
on high an additional 12 hours.
This cures the materials used to manufacture the fire-
place.
NOTICE! Open windows for air circulation during fire-
place break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
H. Heat Management
Burn Rate
The TWILIGHT-II-C has a constant burn rate which is
controlled by the gas valve. Therefore the flame height is
not adjustable.
12
Outdoor Lifestyles by Hearth & Home Technologies • Twilight-II-C Owner's Manual • 2368-971 Rev. o • 1/20
I. Detailed Component Operating
Instructions
IntelliFire™ Ignition System
IntelliFire™, an ignition system exclusively featured in
Heatilator, Heat & Glo & Quadra-Fire products, is an
energy-saving pilot ignition system for gas fireplaces and
inserts. It provides an ignition flame only when needed
and has a battery backup system that supplies power to
spark the ignition flame in the event of a power outage.
Intellifire™ is an intermittent pilot ignition, which is an
electronic system. The term Intermittent is used because
the pilot burner flame is only present when the main
burner is operating. When the main burner is off the pilot
is also off.
NOTICE: Batteries should not be placed in the battery
pack while using the transformer. Remove batteries before
using the transformer, and unplug the transformer before
installing the batteries. Battery polarity must be correct or
module damage will occur.
Appliance ON/OFF:
If an optional remote control or wall control is installed,
it should be used to control the ON/OFF function of the
appliance. Follow instructions included with the installed
control.
To operate the appliance without a wall control or remote
control, use the ON/OFF switch located inside the control
cavity of the appliance. See Figure 3.5.
Access to the ON/OFF switch may vary depending on the
choice of decorative front. In some cases a louver may
need to be opened. In other cases, the decorative front
may need to be removed.
CAUTION! Risk of Electric Shock! Avoid touching wires
and electrical components in appliance control cavity.
Figure 3.5. ON/OFF Switch Location
ON/OFF
SWITCH

Advertisement