Download Print this page

Char-Broil 05101426 User Manual page 8

Turkey/fish fry set

Advertisement

LP tank valve must have:
• Type 1 outlet compatible with regulator or appliance.
• Safety relief valve.
• UL listed Overfill Protection Device (OPD). This OPD
safety feature is identified by a unique triangular hand
wheel. Use only tanks equipped with this type of valve.
LP tank must be arranged for vapor withdrawal and
include collar to protect LP tank valve.
LP (Liquefied Petroleum Gas)
• LP gas is non toxic, odorless and colorless when produced. For Your Safety, LP gas has
been given an odor (similar to rotten cabbage) so that it can be smelled.
• LP gas is highly flammable and may ignite unexpectedly when mixed with air.
LP Tank Filling
• Use only licensed and experienced dealers.
• LP dealer must purge tanks before filling.
• Dealer should NEVER fill LP tank more than 80% of LP tank volume. Volume of propane
in tanks will vary by temperature.
• A frosty regulator indicates gas overfill. Immediately close LP tank valve and call local LP
gas dealer for assistance.
• Do not release liquid propane (LP) gas into the atmosphere. This is a hazardous practice.
• To remove gas from LP tank, contact an LP dealer or call a local fire department for
assistance. Check the telephone directory under "Gas Companies" for nearest certified
LP dealers.
LP Tank Exchange
• Many retailers that sell appliances offer you the option of replacing your empty LP tanks
through an exchange service. Use only those reputable exchange companies that
inspect, precision fill, test and certify their cylinders. Exchange your tank only for an OPD
safety feature-equipped tank as described in the "LP Tank" section of this manual.
• Always keep new and exchanged LP tanks in upright position during use, transit or
storage.
• Leak test new and exchanged LP tanks BEFORE connecting to appliance.
8
OPD Hand Wheel

Advertisement

loading