• Do not use appliance until leak checked.
• If leak is detected at any time,
• If you cannot stop a gas leak, immediately close LP tank valve, leave area of
appliance, and call LP gas supplier or your fire department!
Leak Testing Valves, Hoses and Regulator
1. Turn all control knob(s) to OFF.
2. Be sure regulator is tightly connected to LP tank.
3. Completely open LP tank valve by turning
hand wheel counterclockwise. If you hear
a rushing sound, turn gas off immediately.
There is a major leak at the connection.
Correct before proceeding.
4. Brush soapy solution onto indicated
connections shown at right in
(Reference connection of hose to burner
on page 15.)
5. If "growing" bubbles appear, there is a leak.
Close LP tank valve immediately and retighten
connections. If leaks cannot be stopped, do not
try to repair. Call for replacement parts. Order
new parts by giving the serial number, model
number and name of items needed to the
Warranty Service Center at 1-800-232-3398.
Use only replacement parts specified by
manufacturer.
6. Always close LP tank valve after performing tank leak test by turning hand wheel
clockwise.