AXIS Q6042-S PTZ Dome Network Camera
System Options
Ports & Devices
I/O Ports
The media converter switch provides two configurable input and output ports for connection of external devices. One port is
dedicated for the I/O signals between the media converter switch, the supplied multi-connector cable and the camera. For more
information about the multi-connector cable, see page 59.
To configure the I/O ports, go to System Options > Ports & Devices > I/O Ports. Each port can function as input or output:
Input as Open circuit – The input becomes active when the circuit is grounded by, for example, a REX device. It remains
inactive as long as its normal state equals its current status.
Input as Grounded circuit – The input becomes active when the circuit is opened by for example a monitor.
Output as Open circuit – The output port is in a non-conductive state when its current status is open circuit. The current
status of an output port can be changed by, for example, an action rule.
Output as Grounded circuit – The output port is in a conductive state when its current status is grounded circuit.

Port Status

The list on the System Options > Ports & Devices > Port Status page shows the status of the product's input and output ports.

Maintenance

The Axis product provides several maintenance functions. These are available under System Options > Maintenance.
Click Restart to perform a correct restart if the Axis product is not behaving as expected. This will not affect any of the current
settings.
Note
A restart clears all entries in the Server Report.
Click Restore to reset most settings to the factory default values. The following settings are not affected:
the boot protocol (DHCP or static)
the static IP address
the default router
the subnet mask
the system time
the IEEE 802.1X settings
uploaded applications are kept but must be restarted
Click Default to reset all settings, including the IP address, to the factory default values. This button should be used with caution. The
Axis product can also be reset to factory default using the control button, see Reset to Factory Default Settings on page 58.
To test the product's PTZ mechanics, click Test under PTZ Status.
For information about firmware upgrade, see Upgrade the Firmware on page 61.