Factory/Service Osd Menu And Adjustment; To Enter The Factory Osd Menu; Factory Osd Menu - Hisense LCD42V68PAM Service Manual

Table of Contents

Advertisement

4. Factory/Service OSD Menu and Adjustment

4.1 To enter the Factory OSD Menu

a.. With user's RC
1. Power TV On
2. Press Menu button and call up User OSD Menu
3. Select Audio-> Balance
4. Enter 0->5->3 ->2 in sequence.
Note: If necessary, re-do number keys.
5. Factory OSD appears.
6. Press Menu again and leave factory OSD.
b. With user's RC
7. Power TV On
8. Press Menu button and call up User OSD Menu
9. Select Audio-> Balance
10. Enter 0->5->3 ->2 in sequence.
Note: If necessary, re-do number keys.
11. Factory OSD appears.
12. Press Menu again and leave factory OSD.

4.2 Factory OSD Menu

4.2.1 White Balance
Note: Different source has different WB values. Before adjusting, please change to desired source.
1. Auto Color
For VGA and Component Video sources, WB values must be adjusted. And at others signal sources, the
"auto colour "does not work.
Before adjusting, prepare the signal instruments such as DVD or K-8256 first, and find the video picture
with gray and color bars. Then please change to desired source.
source
1
ADC VGA
2
ADC HDTV
Notes:
a、Press "M" button and enter factory mode.
LCD TV Service Manual
Timing
Pattern
1024*768
gray-3color
720P
gray-3color
Hisense Confidential
- 12 -
Notes
For VGA source
For Component Video