Download Print this page

LG LSXS26336V Service Manual page 64

Advertisement

Crush mode doesn't work
1
Check the loose connection
2
Check the voltage.
(while pushing the lever S/W)
Is voltage correct compared with
table?
INSPECTION POINT
ICE/Water Lever SW
CON6
19
th
pin ~ 20
th
pin
Yes
3
Check the voltage .
Is Duct Motor voltage correct
compared with table?
Duct Motor
Pushing
Duct Motor
CON6
23
th
pin ~ 24
th
pin
Pushing
Yes
Change the
No
PCB
CON6
LEVER
RESULT
S/W
Pushing
0~2V
Not
3.5~5V
Pushing
Change the
No
PCB
CON6
Voltage [V]
9~12V
Not
0~2V
4
Check the resistance value.
Is Dispenser Motor resistance
9.9 ~ 12.1Ω?
Dispenser Motor
Yes
5
Check the voltage.
(while pushing the lever S/W)
Is voltage correct compared with
table?
INSPECTION
LEVER S/W
POINT
Auger Motor (
CON3
th
th
4
pin ~ 7
pin
Yes
4 Check the resistance value.
Is Auger Motor resistance
23~27Ω?
Geared Motor
Black / White
Harness
Yes
6 Explain to customer
Replace
No
Geared Motor
Dispenser Motor
Resistance [Ω]
9.9 ~ 12.1
Change the
No
PCB
CON3
RESULT
Pushing
112~115V
Not
0~2V
Pushing
Replace
No
Geared Motor
Auger Motor
Resistance [Ω]
23~27

Advertisement

loading

This manual is also suitable for:

Lsxs26336d