Micom Function
10. The freezing room fan motor operates at the high speed of RPM during operation of Ice Plus.
11. During 21 hours after Pill Down Operation, F-Room is controlled at Maximum F-Notch normally and F-Fan operates normal
RPM.
12. The light of Ice Plus would be turned off after Ice Plus.
13. Execute defrost immediately in case of defrost signal occurs in Ice Plus and defrosting time is included at execution time 21
hours.
14. If Ice Plus is started during 2nd Load response operation, 2nd Load response operation will be canceled.
15. If the button of Ice Plus in display is turned off, Ice Plus operation will be canceled. The compulsory operation of F notch in the
water tank's preventing frost is prior to the one of Ice Plus.
2-5. Control of variable type of freezing room fan
1. To increase cooling speed and load response speed, MICOM variably controls freezing room fan motor at the high speed of
RPM and standard RPM.
2. MICOM only operates in the input of initial power or special freezing operation or load response operation for the high
speed of RPM and operates in the standard RPM in other general operation.
3. If opening doors of freezing / cold storage room or home bar while fan motor in the freezing room operates, the freezing
room fan motor normally operates (If being operated in the high speed of RPM, it converts operation to the standard RPM).
However, if opening doors of freezing room, the freezing room fan motor stops.
4. As for monitoring of BLDC fan motor error in the freezing room, MICOM immediately stops the fan motor by determining that
the BLDC fan motor is locked or poor if there would be position signal for more than 65 seconds at the BLDC motor.
Then it displays failure (refer to failure diagnosis function table) at the display part of refrigerator, performs re-operation in the
cycle of 30 minutes. If normal operation is performed, poor status is released and refrigerator returns to the initial status
(reset).
2-6. Control of M/C room fan motor
1. The M/C room fan motor performs On/Off control by linking with the Compressor.
2. If ambient temperature is under 34.5 , humidity condition is over 80%, there is not sensor error and the refrigerator do not
operate Ice Plus, first cycle after defrost, first cycle after power on, M/C room fan motor performs ON for 3minitus and OFF for
12minites repeatedly.
3. It controls at various RPM with ambient temperature and humidity condition.
4. Failure sensing method is same with freezing fan motor.(refer to failure diagnosis function table for failure display)
2-7. Door opening alarm
1. Buzzer generates alarm sound if doors are not closed even when more than a minute consecutively has passed with doors
of freezing / cold storage room or home bar opened.
2. Buzzer rings three times in the interval of 0.5 second after the first one-minute has passed after doors are opened and then
repeats three times of On/Off alarm in the cycle of every 30 seconds.
3. If all the doors of freezing / cold storage room or home bar are closed during door open alarm, alarm is immediately
released.
Doors of freezing /
cold storage room
or home bar
BUZZER
2-8 Ringing of button selection buzzer
1. If pressing the front display button, "Ding ~ " sound rings.
2-9. Ringing of compulsory operation, compulsory frost removal buzzer
1. If pressing the test button in the main PCB, "Phi ~ " sound rings.
2. In selecting compulsory operation, alarm sound is repeated and completed in the cycle of On for 0.2 second and Off for 1.8
second three times.
3. In selecting compulsory frost removal, alarm sound is repeated and completed in the cycle of On for 0.2 second , Off for 0.2
second, On for 0.2 second and Off for 1.4 second three times.