Troubleshooting, Servicing And Product Warranty - Mitsubishi Electric SF-PR Series Instruction Manual

3-phase squirrel-cage induction motor
Table of Contents

Advertisement

b. Installation of open type ball bearings or roller bearings
(a) Put the bearing into a clean oil bath and heat it up to about 90°C for 30 minutes. Make absolutely sure that
the temperature does not by all means exceed 100°C. Put the heated bearing on the shaft. Do not move the
bearing until it has completely cooled down. Be sure to put on appropriate protective wears and devices so
as not to get burned when putting the bearing on the shaft. (Before putting the bearing on the shaft, assemble
the shaft box cover and other devices.)
(b) Do not attempt to tighten the lock nut or assemble the bearing on the bracket. Otherwise, the bearing may be
displaced. Make sure that the bearing has completely cooled down before starting the reassembling.
16

. TROUBLESHOOTING, SERVICING AND PRODUCT WARRANTY

(1) Commission all disassembly, reassembly and repairs of the motor to a specialist.
Modifications of the product by the user will not be covered by the Mitsubishi warranty.
(2) Common troubles and remedies are described in Table 16.
If the problem cannot be solved easily, or if there are any unclear points, consult Mitsubishi Sales Office, local agent
or service center.
Notify the following items when making inquiries on troubles or when purchasing spare parts.
a. The type (TYPE), output (kW), No. of poles (POLE), frame No. (FRAME), manufacturing No. (SERIAL) and
manufacturing date (DATE) listed on the motor nameplate.
b. Length of use.
c. Usage site.
d. Place and state of trouble.
e. Name and quantity of spare parts. (Refer to the "17. MOTOR CONSTRUCTION DRAWINGS" for the part
names.)
(3) Warranty period and coverage
a. As a principle, Mitsubishi shall bear the cost of repairs resulting from equipment problems for a period one year
after product delivery, or 18 months from the time of shipment, whichever is shortest.
b. This warranty covers the shipped product only. Responsibility for customer losses or compensation attributed to
breakdown of this product are not covered by the warranty.
c. For important machines, prepare spare machines or motors, or ensure the redundancy.
d. The product modified or repaired by the customer is not covered by the warranty.
Table 16 Troubleshooting and remedial actions
Phenomenon
1. The motor can be
manually rotated in
either direction.
2. An abnormal noise
is heard. A groan
is heard. A groan is
heard when starting.
3. No noise is heard.
4. Motor does
not rotate even
manually.
5. The protection
device functions.
Cause
1. The switch or wire contact is faulty.
2. The fuse or a wire is broken.
3. The stator coil is faulty.
1. One phase is open causing a single phase state.
2. The switch or wire contact is faulty.
3. The fuse or a wire is broken.
4. The stator winding is faulty.
5. There is a constraint in the motor (bearing
damage, etc.)
1. The stator winding is faulty.
2. Each interlock release state is faulty.
3. Power failure.
4. The fuse or two wires are broken.
5. Two or more switches have a faulty contact.
6. Two or more starters have broken wires.
1. Stator and rotor completely contact.
2. Bearings are damaged.
1. The terminal contact is faulty.
2. The stator winding is faulty.
– 19 –
Remedy
1. Adjust or replace the contact section.
2. Inspect and repair or replace.
3. Have specialist repair.
1. Check the switch and power circuit.
2. Adjust or replace the contact section.
3. Inspect and repair or replace.
4. Have specialist repair.
5. Have specialist repair.
1. Have specialist repair.
2. Inspect the circuit.
3. Contact the power company.
4. Inspect and repair or replace.
5. Adjust or replace the contact section.
6. Inspect and repair the starter conductor
section.
1. Have specialist repair.
2. Have specialist repair.
1. Repair the contact section.
2. Have specialist repair.