Service Manual
Steps
Procedure
11.Remove Compressor
a
Remove the 2 screws fixing the gas valve.
Unsolder the welding spot connecting gas valve
and air return pipe and remove the gas valve.
(Note: it is necessary to warp the gas valve when
unsoldering the welding spot.) Remove the 2
Liquid valve
screws fixing liquid valve. Unsolder the weld-
ing spot connecting liquid valve and remove the
liquid valve.
Gas valve
b
Remove the 3 footing screws of the compressor
and remove the compressor.
Compressor
Installation and Maintenance
75