2.4 Cooling and Heating Data Sheet in Rated Frequency

Cooling:
Rated cooling
condition(
o
C) (DB/WB)
Indoor
Outdoor
27/19
35/24
Heating:
Rated heating
o
condition(
C) (DB/WB)
Indoor
Outdoor
20/15
7/6
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.

2.5 Noise Curve

50
40
30
20
Low
Indoor fan motor rotating speed
Technical Information
Pressure of gas pipe
connecting indoor
Model
and outdoor unit
P (MPa)
09/12K
0.8 ~ 1.1
Pressure of gas pipe
connecting indoor and
Model
outdoor unit
P (MPa)
09/12K
2.8 ~ 3.2
Indoor side noise
Middle
High
Supper High
Inlet and outlet pipe
temperature of heat
exchanger
o
T1 (
C)
T2 (
11 to 14
38 to 41
Inlet and outlet pipe
temperature of heat
exchanger
T1 (°C)
T2 (°C)
38 to 41
2 to 5
70
60
50
40
30
20
0
09K
12K
Fan speed
Fan speed
of indoor
of outdoor
unit
unit
o
C)
Super High
High
Fan speed
Fan speed
of indoor
of outdoor
unit
unit
Super High
High
Outdoor side noise
20
40
60
Compressor frequency/Hz
18K
80
100
7

Advertisement