4.2
Modem Unit (MMU)
4.2.1
Overview
The MMU is the indoor part of the Radio Terminal and determines the traffic
capacity and modulation. It is available in the following types:
MMU2 B
MMU2 C
MMU2 D
MMU2 E 155
MMU2 F 155
4/1555-CSH 109 32/1-V1 Uen B 2007-09-14
A traffic capacity agile plug-in unit for C-QPSK
modulation, used for the following traffic capacities in
Mbit/s:
•
2xE1, 4xE1, 8xE1, 17xE1
A traffic capacity and modulation agile plug-in unit,
used for the following modulation schemes and traffic
capacities in Mbit/s:
•
C-QPSK: 2xE1, 4xE1, 8xE1, 17xE1
•
16 QAM: 8xE1, 17xE1, 32xE1
A high capacity PDH plug-in unit, used for the following
modulation schemes and traffic capacities in Mbit/s:
•
16 QAM: 22xE1, 46xE1
•
128 QAM: 35xE1, 75xE1
A high capacity SDH plug-in unit, used for the following
modulation schemes and traffic capacities:
•
16 QAM: STM-1 + 1xE1
•
64 QAM: STM-1 + 1xE1
•
128 QAM: STM-1 + 1xE1
A high capacity SDH plug-in unit with XPIC support,
see Section 4.2.2.10 on page 68, used for the following
modulation schemes and traffic capacities in Mbit/s.
XPIC is only used in combination with 128 QAM, if not
used MMU2 F 155 has the same modulation schemes
and traffic capacities as MMU2 E 155:
•
16 QAM: STM-1 + 1xE1
•
64 QAM: STM-1 + 1xE1
•
128 QAM: 2xSTM-1 + 2xE1 (requires 2xMMU2 E/F
155)
Radio Terminals
61