Ericsson MINI-LINK TN R3 ETSI Technical Description page 47

Table of Contents

Advertisement

3.7.2.1.6
Power
This block interfaces the Power bus and provides secondary voltages for the
unit. All plug-in units have a standard power module providing electronic soft
start and short circuit protection, filter function, low voltage protection, DC/DC
converter and a pre-charge function.
3.7.2.2
Fault Management
The AAU supports the handling of F4/F5 O&M functions for Fault Management
(FM), according to ITU-T I.610. The following FM indications are used:
4/1555-CSH 109 32/1-V1 Uen B 2007-09-14
Alarm Indication Signal (AIS), for reporting defect indications in the forward
direction. The AIS cells at VP or VC level are sent upon one of the following
conditions:
Receiving transmission path defect indications from the physical layer
Detecting Loss of Cell Delineation (LCD)
Detecting Loss of Continuity (LOC)
Remote Defect Indication (RDI), for reporting remote defect indications
in the backward direction. RDI is sent to the far-end from a VPC/VCC
endpoint as soon as it has detected an AIS condition.
Loop Back (LB), allowing for "operations related" information to be inserted
at one location along a VPC/VCC and returned (or looped back) at a
different location, without having to take the connection out-of-service.
This capability is performed by inserting an LB cell at an accessible point
along the VPC/VCC without disrupting the sequence of user cells while
minimizing the user cells transfer delay. This cell is looped back at a
downstream point according to the information contained in its information
field. It is used mainly for:
On-demand connectivity monitoring
Fault localization
Pre-service connectivity verification
The AAU is transparent to Continuity Check (CC) cells, for monitoring
continuity and detection of ATM layer defects in real time.