1173SBM1803A
18-3. Synchronizing Roller Control
The Synchronizing Rollers are started as the Synchronizing Roller Clutch is energized
upon reception of a signal from the Master Board.
CL1
PWB-A PJ11A-4B
PC54
PWB-A PJ15A-2
Control Signal
Energized
Control Signal
M-68
Deenergized WIRING DIAGRAM
L
H
Blocked
Unblocked
L
H
1173T10MCA
1-G
WIRING DIAGRAM
1-H