Electrical Specifications
Power
V
olts
Amps
Blade Shaft RPM
Cycle
Phase
EXTENSION CORD CHART
Wire Gauge
No. 12
No. 10
No. 8
RECOMMENDED
1.
It is recommended that a 15 amp circuit be used while
operating this saw. This will prevent any loss of power
or interruption.
2.
Always plug saw as close as possible to the power
source while operating. This will allow you to receive
optimum electricity.

POWER SAFETY SYSTEM

(M1036 only)
WARNING: The saw should be unplugged before
servicing.
The saw is equipped with an internal electrical safety
system. It is meant to notify the user of an electrical
issue with the machine and to cut power in response to
the following issues:
When power leak/ground fault is detected between
the power switch and the other electrical system, the
error light on the power will flash and power will be
cut. (see figure 14)
When power is abruptly cut from the saw (ie
unintenional power cable pull out, power failure, etc...)
sudden power recovery will not abruptly turn on the
saw. The user must manually turn off the power
switch and turn it back on.
Note to test the power safety system, press the test
button found on the face opposite where the Power and
Error LED indicator is located. Reset from the test by
toggling the power switch from off to on.
M1030/M1036
2 HP
115 V
15 A
2800 RPM
60 Hz
1
Length of Cord
25'
50'
75'
Post
Power and error indicator
fi gure 14
M1036
Black
Green
125V Circuit
breaker
AC-W
Green
Motor
M1030
125V Circuit
breaker
Black
White
Green
Red
ON
COM
Black
Brown
Red
Black-B
IC Board
White-W
Black
Pump
White
Black
Black
Test button
Green
Black
Motor
White
Pump
White
Green
Green
OFF