Crown GMTS-30 Installation & Operation Manual page 7

Gas modular skillets
Hide thumbs Also See for GMTS-30:
Table of Contents

Advertisement

INSTALLATION AND OPERATION MANUAL, GAS SKILLETS, MODELS GMTS-(30, 40, 60)
3.0 INSTALLATION INSTRUCTIONS (Continued)
LEVELLING AND ANCHORING TILTING BRAISING PAN
1.
Place tilting braising pan in the installation position.
2.
Place a carpenter's level on top of the braising pan and turn the adjustable feet to level
braising pan side-to-side and front-to-back.
3.
Mark hole locations on the floor through the anchoring holes provided in the rear flanged
adjustable feet.
4.
Remove tilting braising pan from installation position and drill holes in locations marked on
the floor. (See installation diagram on page 4.) Insert proper anchoring devices (not
supplied).
5.
Place tilting braising pan back in the installation position.
6.
Place carpenter's level on top of braising pan and re-level side-to-side and front to back.
7.
Bolt and anchor tilting braising pan securely to the floor.
8.
Seal bolts and flanged feet with silastic or equivalent compound.
GAS CONNECTIONS
All gas supply connections and any pipe joint compound used must be resistant to the action of
propane gases.
Connect gas supply to the appliance. The gas supply line must be at least equivalent of 3/4"
iron pipe with an incoming pressure of 7" - 14" W.C. (Water Column) for natural gas or 11" - 14"
W.C. (Water Column) for propane gas. Make sure the pipes are clean and free of obstructions,
dirt and piping compound.
Codes require that a gas shutoff valve be installed in the gas line ahead of the tilting braising
pan.
Natural gas and propane gas skillets are equipped with fixed orifices and no adjustment is
necessary. Gas burner manifold is set at 3.5" W.C. (Water Column) for natural gas, and 10"
W.C. (Water Column) for propane gas.
Part No. 10094R2