STOKVIS ENERGY SYSTEMS R6142 Manual

Gas fired condensing boilers
Table of Contents

Advertisement

Quick Links

ECONOFLAME R6000
GAS FIRED
CONDENSING BOILERS
OPTIONS & SYSTEMS
DOCUMENTATION
STOKVIS ENERGY SYSTEMS
96R WALTON ROAD
EAST MOLESEY
SURREY
KT8 0DL
TEL: 08707 707 747
FAX: 08707 707 767
E-MAIL:info@stokvisboilers.com
WEBSITE:www.stokvisboilers.com
03/2008 ART NR. 12 083 431 GB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R6142 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for STOKVIS ENERGY SYSTEMS R6142

  • Page 1 ECONOFLAME R6000 GAS FIRED CONDENSING BOILERS OPTIONS & SYSTEMS DOCUMENTATION STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 08707 707 747 FAX: 08707 707 767 E-MAIL:info@stokvisboilers.com WEBSITE:www.stokvisboilers.com 03/2008 ART NR. 12 083 431 GB...
  • Page 2: Table Of Contents

    Contents Gas condensing boiler R6000 Models and output ....................4 Application possibilities..................4 Value propositions ....................4 Technical description Description ......................4 Technical data ......................5 Dimensions......................6 Declaration of conformity ..................7 Extent of delivery ....................8 Boiler transport .....................8 Boiler installation ....................8 Norms and regulations Regulations ......................9 Maintenance.......................10 Fuel ........................10 Combustion air ....................10...
  • Page 3 Contents Accessories System selection ....................22 Plug & Play kits Kit A: 2x max. Water pressure switch + 1x external high limit thermostat....23 Kit B: max. gas pressure switch................23 Kit C: external high limit thermostat ..............23 Kit D: gas valve leakage tester ................23 Kit E: bypass ......................23 Kit F: wiring for room fan and external gas valve ..........23 Kit G: plate heat exchanger + connection kit............24...
  • Page 4: Gas Condensing Boiler R6000 Models And Output

    Gas condensing boiler R6000 Models and output Application possibilities Value propositions Technical description Models and output Application possibilities Value propositions • The floor standing gas condensing The gas condensing boiler R6000 is Unique reliability boiler R6000 is available in 7 types applicable for alle central heating sys- proven technology with exceptional within an output range from 142 until...
  • Page 5: Technical Data

    Technical discription Technical data R6380 R6142 R6190 R6237..R6285 R6475 R6539 Nominal heat output at 80-60ºC max/min* 142.1/23.3 190.1/39.5 237.2/39.5 285.2/39.5 380.2/76.6 475.3/76.6 539.0/76.6 Nominal heat output at 75-60ºC max/min* 142.2/23.5 190.3/39.5 237.4/39.5 285.5/39.5 380.6/76.6 475.8/76.6 539.6/76.6 Nominal heat output at 40/30ºC max/min* 150.7/26.7 201.6/45.2 251.4/45.1 302.3/45.2 403.1/87.7 503.9/87.7 571.5/87.7...
  • Page 6: Dimensions

    Technical description Dimensions Electrical connections Dimensions R6142...R6190..R6237...R6285..R6380...R6475..R6539 Gas supply 1105 1260 1470 1220 1435 1585 1735 Water supply Water return (Cold) 127.5 127.5 137.5 137.5 187.5 187.5 187.5 Air Intake 1480 1480 1500 1500 1500 1500 1500 Water 2nd return (Hot) Boiler water drain valve 1/2"...
  • Page 7: Declaration Of Conformity

    Technical description Declaration of conformity...
  • Page 8: Extent Of Delivery

    Technical description Extent of delivery Boiler transport Boiler installation Standard boiler A boiler delivery package contains the following components: Component Pcs. Package Boiler fully assembled and tested Mounted on wooden blocks with wooden border, sealed in PE foil Adjustable feet Mounted on frame of the boiler Syphon for condensate connection Cardboard box on top of heatexchanger...
  • Page 9: Norms And Regulations Regulations

    Norms and regulations − The R6000 boiler is CE approved and Norms and regulations EN 61000-3-2 applies to the following European When installing and operating the Electromagnetic compatibility (EMC) - standards: boiler, all applicable norms (european Part 3-2: Limits - Limits for harmonic −...
  • Page 10: Maintenance

    Norms and regulations Maintenance Fuel Combustion air Water quality Maintenance Fuel Combustion air Regular maintenance is necessary to The gas condensing boiler R6000 is The gas condensing boiler R6000 can secure a safe and economical operati- applicable for natural gases H, L and be used in both non-roomsealed and on of the installation.
  • Page 11: Noise Protection

    Norms and regulations Noise protection Antifreeze The R6000 is supplied with adjustable Noise protection The gas condensing boiler R6000 is feet, which also prevent the transmissi- equipped with a patented premix bur- on of vibration noise from the boiler into ner.
  • Page 12: Flue Gas System Requirements And Regulations

    Flue gas system Requirements and regulations Materials Flue gas data Requirements and regulations Materials Regulations for the construction of flue Exclusively materials, which are heat gas systems are very different for each resistant and resistant to flue gases country. It should be ensured that all and aggressive condensate, may be national regulations with regard to flue used.
  • Page 13: Dimensioning

    Flue gas system Dimensioning VERSION 1 Dimensioning Calculation base: When dimensioning a flue gas system, it’s necessary to perform a calculation Total connection length in boiler room ≤ 1.5 m; check of the flue gas system in order to 2x 87°-bend verify if the choosen system is appli- Maximum permissible height (h) of flue gas cable.
  • Page 14: Neutralisation General

    Neutralisation General Neutralisation systems Standard neutralisation system (DN) Neutralisation system with pump (HN) The maximum amount of condensate General Condensate, created by the R6000, for each boiler type can be found in the should be drained into the public drai- chapter „Technical data“.
  • Page 15: Hydraulic Connection Hydraulic Resistance

    Hydraulic connection Hydraulic resistance ∆T-measurement ∆p-measurement Water flow data Hydraulic resistance 100.0 The hydraulic resistance depends on the flow rate through the boiler and the boiler type. In the graph the resistance for a specific flow rate can be found. The R6000 is able to control a speed controlled pump via a 0-10VDC signal.
  • Page 16: Hydraulic Connection Into A System

    Hydraulic connection Hydraulic connection into a system Standard Bypass - Not applicable • Details to the 3 possibilities mentioned Hydraulic connection into a system Standard, with low loss header or The R6000 must be connected in such a above, can be found in the next secti- plate heat exchanger way, that a minimum flow rate of 30% ons.
  • Page 17: Split System

    11.5 18.5 30.8 Necessary head pump P2: R = R2 + R1 at Q2 at (Q1+Q2) System Necessary head pump P1: R1 at (Q1+Q2) 100.00 100.00 R6142-R6237 R6380-R6539 10.00 10.00 R6380-R6539 1.00 R6142-R6237 0.10 1.00 0.01 0.10 0.00 1.00 10.00 100.00...
  • Page 18: Controls Basic Controls And Connections

    Controls Basic controls and connections Control by building managemant system Boiler enable signal Temperature or capacity setpoint • When additional control of secundary Basic controls and connections Electronic high limit thermostat The standard version of the R6000 is heating zones or cascade systems are •...
  • Page 19: Capacity Feedback Signal

    Controls Capacity feedback signal OK/Alarm output signal Weather compensated controller BM8 Capacity feedback signal, terminals 111-112 (0-10VDC) This signal is available at the mentio- ned terminals, when the burner is acti- ve. The following graph shows the va- lue of the signal. OK/Alarm output signal, terminals 25-26-27 (volt free) At terminal 25 (COM), a desired voltage...
  • Page 20: Heating Zone Controller E8

    Controls Heating zone controller E8 For room temperature optimisation of In case of heating systems with more Heating zone controller E8 The R6000 can be extended with an E8 each heating zone, an additional roo- than two heating zones, an additonal kit controller for extended control of two munit BM8 can be connected via bus with E8 in a wall hung box is available.
  • Page 21: Cascade Manager Kkm8

    Controls Cascade manager KKM8 Cascade manager KKM8 The KKM8 can also be used for casca- In case of heating systems with more The R6000 can be equipped with a de control only, without using the possi- than two heating zones, an additonal kit KKM8 cascade manager for cascade bility to control secundary heating zo- with E8 in a wall hung box is available.
  • Page 22: Accessories System Selection

    1x wiring for room fan and external gas valve 12082969 1x plate heat exchanger + connection kit 12082980 12082991 12083002 12088249 (R6142-R6237 = dT10K, R6285-R6539 = dT15K) 1x plate heat exchanger + connection kit (dT20K) 12082980 12083002 12083013 1x header + connection kit 12083024...
  • Page 23: Plug & Play Kits

    Accessories Plug & play kits The connection piece is pre-assembled Kit A: 2x max. Water pressure switch + 1x external high limit thermostat with the following components: • The kit includes a connection piece, 2x maximum water pressure switch which can be connected the flow con- •...
  • Page 24: Kit G: Plate Heat Exchanger + Connection Kit

    The kit contains a plate heat ex- changer including connection mate- /h] [kPa] [m /h] [kPa] [m /h] [kPa] rial, automatic de-aerator and expan- R6142 12.2 30.4 - sion vessel. For multiple assembly variations two 90º bends are in- R6190 16.2 28.8 - 14.0...
  • Page 25: Kit I: Bm8

    Accessories Plug & play kits Kit I: BM8 Kit K: E8 extended heating zone con- Kit L: pump 3-step The kit contains a BM8 weather com- trol The kit includes a 3-step pump includ- pensated controller including connecti- The kit contains a E8 weather compen- ing connection material with connection on material, outside temperature sen- sated heating zone controller including...
  • Page 26 Accessories Plug & play kits UPS32-60F UPS32-120F UPS50-120F UPS65-120F...
  • Page 27: Kit M: Speed Controlled Pump

    Accessories Plug & play kits The pump is electrically wired, and can Kit M: speed controlled pump The kit includes a speed controlled be connected directly to the terminals in pump including connection material the boiler. Consult the wiring diagram with connection possibility for an ex- for more details.
  • Page 28: Kit N/O/P/Q: Safety Valve (3-4-5-6 Bar) Tüv + Manometer + De-Aerator

    Accessories Plug & play kits MAGNA40-100F MAGNA50-120F Kit N/O/P/Q: safety valve (3-4-5-6 The connection piece is pre-assembled bar) TÜV + manometer + de-aerator with the following components: The kit includes a connection piece, • 1x safety valve (3-4-5-6 bar) TÜV which can be connected the flow con- •...
  • Page 29: Set S: Logon B

    Accessories Plug & play kits Set S: LOGON B - NOT APPLICABLE The R6000 can be extended with a LO- GON B controller for extended control of two heating zones and sanitary hot water operation. The LOGON B combi- nes weather compensated operation with control of two heating zones and the control of a secundary hot water circulation pump.
  • Page 30: Connection Possibilities

    Connection possibilities Low loss header Boiler type Boiler type Boiler type R6142-R6237 1233 R6142-R6237 R6142-R6237 R6285-R6380 1299 R6285-R6380 1096 R6285-R6380 1119 R6475-R6539 1299 R6475-R6539 1096 R6475-R6539 1119 Boiler type Boiler type Boiler type R6142-R6237 1191 R6142-R6237 R6142-R6237 R6285-R6380 1320 R6285-R6380...
  • Page 31: Plate Heat Exchanger

    Connection possibilities Plate heat exchanger Boiler type Boiler type Boiler type R6142-R6237 1421 R6142-R6237 R6142-R6237 1047 R6285-R6380 1667 R6285-R6380 1133 R6285-R6380 1222 R6475-R6539 1542 R6475-R6539 1073 R6475-R6539 1278 Boiler type Boiler type Boiler type R6142-R6237 1379 R6142-R6237 R6142-R6237 1005 R6285-R6380...
  • Page 32: Installation Examples 2-A-C: 1 Heating Zone + Low Loss Header

    Installation examples 2-A-C: 1 heating zone + low loss header 2-A-C: 1 heating zone + low loss header Description • R6000 with low loss header • Weather compensated control (E8 or LOGON B) • 1 mixed heating zone Tips • Complete accessory kits with low loss header are available for ∆T=10-20K (see chapter „Accessories“).
  • Page 33: 2-5-A-C: 1 Heating Zone And Sanitary Hot Water + Low Loss Header

    Installation examples 2-5-A-C: 1 heating zone and sanitary hot water + low loss header 2-5-A-C: 1 heating zone and sanitary hot water + low loss header Description • R6000 with low loss header • Weather compensated control (E8 or LOGON B) •...
  • Page 34: 4-A-C: 2 Heating Zones + Low Loss Header

    Installation examples 4-A-C: 2 heating zones + low loss header 4-A-C: 2 heating zones + low loss header Description • R6000 with low loss header • Weather compensated control (E8 or LOGON B) • 2 mixed heating zones Tips • Complete accessory kits with low loss header are available for ∆T=10-20K (see chapter „Accessories“).
  • Page 35: 4-5-A-C: 2 Heating Zones And Sanitary Hot Water + Low Loss Header

    Installation examples 4-5-A-C: 2 heating zones and sanitary hot water + low loss header 4-5-A-C: 2 heating zones and sanitary hot water + low loss header Description • R6000 with low loss header • Weather compensated control (E8 or LOGON B) •...
  • Page 36: A-C: Boiler Control Via 0-10Vdc + Low Loss Header

    Installation examples A-C: Boiler control via 0-10VDC + low loss header A-C: Boiler control via 0-10VDC + low loss header Description • R6000 with low loss header Tips • Complete accessory kits with low loss header are available for ∆T=10-20K (see chapter „Accessories“).
  • Page 37: 2-B-C: 1 Heating Zone + Plate Heat Exchanger

    Installation examples 2-B-C: 1 heating zone + plate heat exchanger 2-B-C: 1 heating zone + plate heat exchanger Description • R6000 with plate heat exchanger • Weather compensated control (E8 or LOGON B) • 1 mixed heating zone Tips • Complete accessory kits with plate heat exchanger are available for ∆T=10-20K (see chapter...
  • Page 38: 2-5-B-C: 2 Heating Zones And Sanitary Hot Water + Plate Heat Exchanger

    Installation examples 2-5-B-C: 2 heating zones and sanitary hot water + plate heat exchanger 2-5-B-C: 2 heating zones and sanitary hot water + plate heat exchanger Description • R6000 with plate heat exchanger • Weather compensated control (E8 or LOGON B) •...
  • Page 39: 4-B-C: 2 Heating Zones + Plate Heat Exchanger

    Installation examples 4-B-C: 2 heating zones + plate heat exchanger 4-B-C: 2 heating zones + plate heat exchanger Description • R6000 with plate heat exchanger • Weather compensated control (E8 or LOGON B) • 2 mixed heating zones Tips • Complete accessory kits with plate heat exchanger are available for ∆T=10-20K (see chapter...
  • Page 40: 4-5-B-C: 2 Heating Zones And Sanitary Hot Water + Plate Heat Exchanger

    Installation examples 4-5-B-C: 2 heating zones and sanitary hot water + plate heat exchanger 4-5-B-C: 2 heating zones and sanitary hot water + plate heat exchanger Description • R6000 with plate heat exchanger • Weather compensated control (E8 or LOGON B) •...
  • Page 41: B-C: Boiler Control Via 0-10Vdc + Plate Heat Exchanger

    Installation examples B-C: Boiler control via 0-10VDC + plate heat exchanger B-C: Boiler control via 0-10VDC + plate heat exchanger Description • R6000 with plate heat exchanger Tips • Complete accessory kits with plate heat exchanger are available for ∆T=10-20K (see chapter „Accessories“).
  • Page 42: 4-5-A-C-E: 2 Heating Zones And Sanitary Hot Water + Cascade Via Low Loss Header

    Installation examples 4-5-A-C-E: 2 heating zones and sanitary hot water + cascade via low loss header 4-5-A-C-E: 2 heating zones and sanitary hot water + cascade via low loss header Description • 2x R6000 with low loss header • Cascade control + weather compen- sation (KKM8) •...
  • Page 43: Extension 2 Heating Zones

    Installation examples Extension 2 heating zones Extension 2 heating zones Description • Weather compensated controller with wall hung box (E8 or LOGON B) • Extension of 2 heating zones Tips • The extension controller should al- ways be used in combination with an integrated controller (E8/KKM8/ LOGON B).
  • Page 44: Norms

    Norms Germany: Austria: Italy: − − Sicurezza degli impianti DIN EN 483 ÖNORM H 5152: Brennwert- − − Feuerungsanlagen, Planungshilfen Legge 5 marzo 1990 n. 46 DIN EN 677 − − − ÖNORM M 7443: Gasgeräte mit D.P.R. 6/12/91 n. 447 DIN EN 13384-1 atm.Brenner Teil 1, 3, 5, 7 −...