4. Connect a drain hose extension (not included)
to the drain joint to redirect water from the
unit during heating mode.
If the drain joint doesn't come with a rubber
seal (see Fig. 5.12 - B ), do the following:
1. Insert the drain joint into the hole in the base
pan of the unit. The drain joint will click in
place.
2. Connect a drain hose extension (not included)
to the drain joint to redirect water from the
unit during heating mode.
NOTE: Make sure the water drains to a safe
location where it will not cause water damage
or a slipping hazard.
Seal
Drain joint
(A)
Notes On Drilling Hole In Wall
You must drill a hole in the wall for the
refrigerant piping, and the signal cable that will
connect the indoor and outdoor units.
Determine the location of the wall hole
1.
based on the location of the outdoor unit.
Using a 65-mm (2.5") core drill, drill a hole
2.
in the wall.
NOTE: When drilling the wall hole, make
sure to avoid wires, plumbing, and other
sensitive components.
Place the protective wall cu in the hole.
3.
This protects the edges of the hole and will
help seal it when you nish the installation
process.
Page 20
Base pan hole of
outdoor unit
Seal
(B)
Fig. 5.12