Fig. 5.8
(Wall or obstacle)
>45.7cm / 18"
>45.7cm / 18"
Air inlet
Air inlet
Fig. 5.9
Table 5.2: Length Specifications of Vertical
Discharge Outdoor Unit (unit: mm/inch)
MODEL
W
18
554/21.8
24
554/21.8
36
554/21.8
36
600/23.6
48
710/28
60
710/28
NOTE: The minimum distance between the
outdoor unit and walls described in the
installation guide does not apply to airtight
rooms. Be sure to keep the unit unobstructed
in at least two of the three directions (M, N, P)
(See Fig. 5.10)
D
Air inlet
>45.7cm / 18"
Air inlet
>45.7cm / 18"
DIMENSIONS
H
D
633/25
554/21.8
633/25
554/21.8
759/29.8
554/21.8
633/25
600/23.6
759/29.8
710/28
843/33
710/28
M
N
Fig. 5.10
Rows of series installation
Table 5.3 The relations between H, A and L
are as follows.
L
L ≤ 1/2H
L ≤ H
1/2H < L ≤ H
Can not be installed
L > H
H
Drain Joint Installation
If the drain joint comes with a rubber seal
(see Fig. 5.12 - A ), do the following:
1. Fit the rubber seal on the end of the drain joint
that will connect to the outdoor unit.
2. Insert the drain joint into the hole in the base
pan of the unit.
3. Rotate the drain joint 90° until it clicks in place
facing the front of the unit.
P
A
25 cm / 9.8" or more
30 cm / 11.8" or more
Fig. 5.11