10. 4HS use and programming
CM software is extremely simple to use, but allows a wide variety of parameters to be set for ideal system
calibration.
Setting Parameters are organized in 2 levels:
1: Installer level
A password is required for this level; these parameters are adjustable by trained professionals
Default password:
From the menu a different password can be set up.
2. Advanced level
A second and different password is required; improper setting of these advanced parameters could
compromise the integrity and the life of CM and pump;
Default password
It is possible to set up a different password.
Installer and Advanced levels can be entered only with the correct password; otherwise, it is impossible to set
up and/or modify any parameters (they can be only displayed).
10.1 Display
Scroll up
Scroll down
ENTER
Screen is a back-lit LCD displaying 2 rows of 16 digits each. Alarms are indicated by an audible signal.
10.2 Initial setting
When the 4HS is switched on for the first time, the initial setting menu is displayed for the initial setting of
parameters to configure pumps and plant characteristics.
If the initial setting procedure is not ended properly, it is impossible to run the pump.
Initial setting procedure can be repeated.
16
001
002
START motor
STOP motor
Menu exit
Alarms reset