EPSON Perfection 1240U
Electrical
Input voltage range DC 24 V
Rated input
0.8 A
current
Power
Approx. 20 W, operating
consumption
approx. 10 W, standby
Note:
Check the label on the back of the scanner for voltage
information.
Environmental
Temperature
Operation: 41 to 95 °F (5 to 35 °C)
Storage: –13 to 140 °F (–25 to 60 °C)
Humidity
Operation: 10% to 80%
(without
Storage: 10% to 85%
condensation)
Operating
Ordinary office or home conditions; avoid
conditions
extreme dust, direct sunlight, and strong
light sources.

Safety Approvals

Safety Standards
120 V model
UL 1950
CSA C22.2 No. 950
EMC FCC part 15 subpart B class B
230 V model
EN 60950
EMC EN 55022 (CISPR Pub 22) class B
CE marking
230 V model
EMC Directive 89/336/EEC
EN 55022 Class B
EN 50082-1

USB Interface

Interface type
Universal Serial Bus Specification
Revision 1.1
EPSON Perfection 1240U
2 -
CSA C108.8 class B
AS/NZS 3548 class B
IEC 60801-2
IEC 60801-3
IEC 60801-4
Configuration
Element
Description
Configuration
Characteristics: Self-powered
Remote wake up feature: Not supported
Maximum power consumption from VBUS: 2mA (5V)
Interface
No alternate setting
Number of endpoints used by this interface
(excluding endpoint 0): 2
Class: Vendor specific
Endpoint 1
Bulk IN transfer
Maximum data transfer size: 64 bytes
Endpoint 2
Bulk OUT transfer
Maximum data transfer size: 64 bytes
String
Language ID: US English
Descriptor
1: Manufacturer: "EPSON"
2: Product: "Perfection 1240U"
Electrical
Full Speed mode (12Mbit/s) of Universal
standard
Serial Bus Specification Revision 1.1
Connector type
One receptacle (Type B)
Connector pin arrangement
Pin number
1
2
3
4
Initialization
The scanner can be initialized (returned to
methods
a fixed set of conditions) in the following
ways:
Hardware
* The scanner is plugged in.
initialization
* The USB cable is unplugged from the USB port on the
scanner.
Software
* Software sends the ESC @ (initialize the scanner)
initialization
command.
* The scanner receives a Bus Reset from the USB
interface.

AC Adapter Specifications

Basic Specifications (Model A110B)
Temperature
41 to 95° F (5 to 35° C)
Dimensions
2.3
(5.8
Weight
Approx. 0.55 lb (0.25 kg, without AC
plug)
10/00
Signal
Connector
VCC
DATA
+DATA
GND
4.3
3.4 inches
10.8
3.4 cm)