Parameters - Emerson Dixell XB Series Installing And Operating Instructions

Blast chiller
Table of Contents

Advertisement

8.5 OTHER KEYS
LIGHT (4): push the LIGHT (4) key to
switch the light on and off. The status of
the light is monitored by the yellow LED
upper the key.
AUX (8): push the AUX (8) key to
switch the ausiliary on and off. The
status of the auxiliary relay is monitored
by the yellow LED upper the key.
PRINTER / H (7): push the PRINTER
key when the keyboard is connected to
the controller, to enable or disable the
printer.
PRINTER CONFIGURATION MENU
Push the PRINTER (7) key for few
seconds
to
enter
configuration menu.
The itP, label is displayed, use the
ARROW
keys
to

parameters:

-
To modify: push the SET
key and then the ARROW
keys.
-
To confirm: push the SET
key.
To exit the Printer menu: push both
SET+UP keys or wait for 5 sec.
8.6 HOW TO START A MANUAL DEFROST.
Assure that none cycle is active or the hold mode is running.
1. Keep UP key pressed a few seconds.
NOTE: the defrost will not be done if the temperature detected by the evaporator probe is higher than EdF
(stop defrost temperature) parameter.
8.7 OTHER FUNCTIONS OF KEYBOARD
+
+
+
1592006207 XB570L GB r1.1 23.03.2015
the
printer
browse
the
To lock & unlock the keyboard Pon/PoF
To enter the programming mode when
stand-by
Each parameter present in the Pr2 can be removed or put into
"Pr1" (user level) by pressing SET+DOWN.
To return to the previous menu.
UP key: browse the menu:
- itP=time printing interval.
- PbP=data to print.
- PAr=enabled the printing of the
parameter map.
- CyC=enabled the printing of
cycle parameters.
- PtH=enabled the printing during
the holding phase.
- PrS=level Pr1 o Pr2.
- Pnu=number of printing.
DOWN key back to the previous
label.
the controller is in
XB570L
5/20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dixell xb570lDixell xb570l-5r0c1-x378254

Table of Contents